Influence of PDMS encapsulation on the sensitivity and frequency range of fiber-optic interferometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F16%3A86098910" target="_blank" >RIV/61989100:27240/16:86098910 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.2243170" target="_blank" >http://dx.doi.org/10.1117/12.2243170</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2243170" target="_blank" >10.1117/12.2243170</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of PDMS encapsulation on the sensitivity and frequency range of fiber-optic interferometer
Popis výsledku v původním jazyce
Fiber-optic sensors are one of the dynamically developing areas of photonics and photonic applications. This group of sensors can also include fiber-optic interferometers which enable very sensitive sensing. They are entirely passive regarding power supply, and immune to electromagnetic interference. This type of sensor is dependent on the phase change. It mostly used in the field which requires high measurement accuracy. We can achieve a change of sensitivity in the order of 10-8. The fundamental problem of fiber-optic interferometry is a design and imposition (encapsulation) of the measuring arm and reference arm of the interferometer. Polydimethylsiloxane elastomer (PDMS) is one of the possibilities to encapsulation of the sensory arm. Two-component PDMS Sylgard 184 is used type. The article analyzes the effect of encapsulation into a PDMS of the measuring arm of the interferometer to frequency response and sensitivity of the Mach-Zehnder interferometer with the division of power in a ratio of 1:1 (measuring arm and reference arm). Input power set to a reference value of 1 mW, this value was constant for all performed experimental measurements. The generator of a harmonic signal with fixed amplitude signal used for analysis of the frequency characteristic of the interferometer. The application written in LabView development environment, evaluated the amplitude-frequency spectra of the signal. Repeated test of assembled prototype verified the measured results.
Název v anglickém jazyce
Influence of PDMS encapsulation on the sensitivity and frequency range of fiber-optic interferometer
Popis výsledku anglicky
Fiber-optic sensors are one of the dynamically developing areas of photonics and photonic applications. This group of sensors can also include fiber-optic interferometers which enable very sensitive sensing. They are entirely passive regarding power supply, and immune to electromagnetic interference. This type of sensor is dependent on the phase change. It mostly used in the field which requires high measurement accuracy. We can achieve a change of sensitivity in the order of 10-8. The fundamental problem of fiber-optic interferometry is a design and imposition (encapsulation) of the measuring arm and reference arm of the interferometer. Polydimethylsiloxane elastomer (PDMS) is one of the possibilities to encapsulation of the sensory arm. Two-component PDMS Sylgard 184 is used type. The article analyzes the effect of encapsulation into a PDMS of the measuring arm of the interferometer to frequency response and sensitivity of the Mach-Zehnder interferometer with the division of power in a ratio of 1:1 (measuring arm and reference arm). Input power set to a reference value of 1 mW, this value was constant for all performed experimental measurements. The generator of a harmonic signal with fixed amplitude signal used for analysis of the frequency characteristic of the interferometer. The application written in LabView development environment, evaluated the amplitude-frequency spectra of the signal. Repeated test of assembled prototype verified the measured results.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE - The International Society for Optical Engineering. Volume 9994
ISBN
978-1-5106-0392-9
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1-7
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Edinburgh
Datum konání akce
28. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—