Measurements of generated energy/electrical quantities from locomotion activities using piezoelectric wearable sensors for body motion energy harvesting
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F16%3A86099371" target="_blank" >RIV/61989100:27240/16:86099371 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3390/s16040524" target="_blank" >http://dx.doi.org/10.3390/s16040524</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s16040524" target="_blank" >10.3390/s16040524</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurements of generated energy/electrical quantities from locomotion activities using piezoelectric wearable sensors for body motion energy harvesting
Popis výsledku v původním jazyce
In this paper, two different piezoelectric transducers-a ceramic piezoelectric, lead zirconate titanate (PZT), and a polymeric piezoelectric, polyvinylidene fluoride (PVDF)-were compared in terms of energy that could be harvested during locomotion activities. The transducers were placed into a tight suit in proximity of the main body joints. Initial testing was performed by placing the transducers on the neck, shoulder, elbow, wrist, hip, knee and ankle; then, five locomotion activities-walking, walking up and down stairs, jogging and running-were chosen for the tests. The values of the power output measured during the five activities were in the range 6 μW-74 μW using both transducers for each joint. (C) 2016 by the authors; licensee MDPI, Basel, Switzerland.
Název v anglickém jazyce
Measurements of generated energy/electrical quantities from locomotion activities using piezoelectric wearable sensors for body motion energy harvesting
Popis výsledku anglicky
In this paper, two different piezoelectric transducers-a ceramic piezoelectric, lead zirconate titanate (PZT), and a polymeric piezoelectric, polyvinylidene fluoride (PVDF)-were compared in terms of energy that could be harvested during locomotion activities. The transducers were placed into a tight suit in proximity of the main body joints. Initial testing was performed by placing the transducers on the neck, shoulder, elbow, wrist, hip, knee and ankle; then, five locomotion activities-walking, walking up and down stairs, jogging and running-were chosen for the tests. The values of the power output measured during the five activities were in the range 6 μW-74 μW using both transducers for each joint. (C) 2016 by the authors; licensee MDPI, Basel, Switzerland.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
15
Strana od-do
—
Kód UT WoS článku
000375153700104
EID výsledku v databázi Scopus
2-s2.0-84963746814