Interactive application for simulation of each type of defibrillation impulses by using LabVIEW
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F16%3A86100111" target="_blank" >RIV/61989100:27240/16:86100111 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-32703-7_183" target="_blank" >http://dx.doi.org/10.1007/978-3-319-32703-7_183</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-32703-7_183" target="_blank" >10.1007/978-3-319-32703-7_183</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interactive application for simulation of each type of defibrillation impulses by using LabVIEW
Popis výsledku v původním jazyce
Standard defibrillation is use on human body during fibrillation. The success of defibrillation is dependent on many factors which influence defibrillation. These factors include the impedance of the patient's chest, elapsed time from cardiac arrest until start of applying the defibrillation's discharges, the type of defibrillation pulse, which is defined by the shape, amplitude, initial phase and also the pulse length and ratio of phases. This issue of applying defibrillation pulses, a brief description and user's feedback has been processed in the application which was created and is described in this article. Application gives possibility try to apply defibrillation without any risk and it also gives feedback about success of the applied defibrillation pulses. (C) Springer International Publishing Switzerland 2016.
Název v anglickém jazyce
Interactive application for simulation of each type of defibrillation impulses by using LabVIEW
Popis výsledku anglicky
Standard defibrillation is use on human body during fibrillation. The success of defibrillation is dependent on many factors which influence defibrillation. These factors include the impedance of the patient's chest, elapsed time from cardiac arrest until start of applying the defibrillation's discharges, the type of defibrillation pulse, which is defined by the shape, amplitude, initial phase and also the pulse length and ratio of phases. This issue of applying defibrillation pulses, a brief description and user's feedback has been processed in the application which was created and is described in this article. Application gives possibility try to apply defibrillation without any risk and it also gives feedback about success of the applied defibrillation pulses. (C) Springer International Publishing Switzerland 2016.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings. Volume 57
ISBN
978-3-319-32701-3
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
940-943
Název nakladatele
Springer Verlag
Místo vydání
London
Místo konání akce
Pafos
Datum konání akce
31. 3. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—