Comparison of the FBG sensor encapsulated into PDMS and FBG sensor glued on the plexiglass pad for respiratory and heart rate monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10236035" target="_blank" >RIV/61989100:27240/17:10236035 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85029468225&origin=resultslist&sort=plf-f&src=s&sid=2caa48d7d94cdb9e5d3614e110de5ab2&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=5&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85029468225&origin=resultslist&sort=plf-f&src=s&sid=2caa48d7d94cdb9e5d3614e110de5ab2&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=5&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2280778" target="_blank" >10.1117/12.2280778</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of the FBG sensor encapsulated into PDMS and FBG sensor glued on the plexiglass pad for respiratory and heart rate monitoring
Popis výsledku v původním jazyce
Authors of this article focused on the use of fiber-optic technology for monitoring heart and respiratory rate of the human body. The article describes an innovative method of encapsulating fiber Bragg grating (FBG) into polymer polydimethylsiloxane (PDMS) and comparison of this measuring probe with an FBG sensor glued on the plexiglass pad. The team of authors offers a solution which is basically focused on the monitoring of long-term ill patients with a minimum of physical movement load. Real data were acquired from a group of 10 volunteers with their written consent in the laboratory environment. Acquired data was compared by the Bland-Altman method
Název v anglickém jazyce
Comparison of the FBG sensor encapsulated into PDMS and FBG sensor glued on the plexiglass pad for respiratory and heart rate monitoring
Popis výsledku anglicky
Authors of this article focused on the use of fiber-optic technology for monitoring heart and respiratory rate of the human body. The article describes an innovative method of encapsulating fiber Bragg grating (FBG) into polymer polydimethylsiloxane (PDMS) and comparison of this measuring probe with an FBG sensor glued on the plexiglass pad. The team of authors offers a solution which is basically focused on the monitoring of long-term ill patients with a minimum of physical movement load. Real data were acquired from a group of 10 volunteers with their written consent in the laboratory environment. Acquired data was compared by the Bland-Altman method
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE. Volume 10445
ISBN
978-1-5106-1354-6
ISSN
0277-786X
e-ISSN
neuvedeno
Počet stran výsledku
8
Strana od-do
1-8