Noninvasive fetal heart rate monitoring: Validation of phonocardiography-based fiber-optic sensing and adaptive filtering using the nlms algorithm
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10236101" target="_blank" >RIV/61989100:27240/17:10236101 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/17:00100124 RIV/65269705:_____/17:00068499
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85030549140&origin=resultslist&sort=plf-f&src=s&sid=181567d2da1a33f250897a6fefa5be8d&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=4&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85030549140&origin=resultslist&sort=plf-f&src=s&sid=181567d2da1a33f250897a6fefa5be8d&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=4&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15598/aeee.v15i3.2195" target="_blank" >10.15598/aeee.v15i3.2195</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Noninvasive fetal heart rate monitoring: Validation of phonocardiography-based fiber-optic sensing and adaptive filtering using the nlms algorithm
Popis výsledku v původním jazyce
Here we present the evaluation results of our novel noninvasive phonocardiographic-based fiber-optic sensor for fetal Heart Rate (fHR) detection using adaptive filtering and the NLMS Algorithm. The sensor uses two interferometric probes encapsulated inside a PolyDiMethylSiloxane (PDMS) polymer. Based on real data acquired from pregnant women in a suitable research laboratory environment, once they had given their written informed consents, we created a simplified dynamic signal model of the distribution of maternal and fetal heart sounds inside the maternal body. Building upon this signal model, we verified the functionality of our novel fiber-optic sensor and its associated adaptive filtering system using the NLMS Algorithm. The main reason why we chose this technology to develop our system was that it allows monitoring the fHR without exposing the fetus to any external energies or radiation (in contrast to the ultrasound-based Cardiotocography Method). We used objective criteria such as: Signal to Noise Ratios: SNRin, SNRout and Percentage Root-mean-square Difference (PRD) for our evaluations.
Název v anglickém jazyce
Noninvasive fetal heart rate monitoring: Validation of phonocardiography-based fiber-optic sensing and adaptive filtering using the nlms algorithm
Popis výsledku anglicky
Here we present the evaluation results of our novel noninvasive phonocardiographic-based fiber-optic sensor for fetal Heart Rate (fHR) detection using adaptive filtering and the NLMS Algorithm. The sensor uses two interferometric probes encapsulated inside a PolyDiMethylSiloxane (PDMS) polymer. Based on real data acquired from pregnant women in a suitable research laboratory environment, once they had given their written informed consents, we created a simplified dynamic signal model of the distribution of maternal and fetal heart sounds inside the maternal body. Building upon this signal model, we verified the functionality of our novel fiber-optic sensor and its associated adaptive filtering system using the NLMS Algorithm. The main reason why we chose this technology to develop our system was that it allows monitoring the fHR without exposing the fetus to any external energies or radiation (in contrast to the ultrasound-based Cardiotocography Method). We used objective criteria such as: Signal to Noise Ratios: SNRin, SNRout and Percentage Root-mean-square Difference (PRD) for our evaluations.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.20.0217" target="_blank" >EE2.3.20.0217: Rozvoj excelence vědeckovýzkumného týmu Telekomunikační techniky ve vazbě na zahraniční spolupráci</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advances in Electrical and Electronic Engineering
ISSN
1336-1376
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
544-552
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85030549140