Mitigation of interferences between electric regulated drainage and track circuits
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10236674" target="_blank" >RIV/61989100:27240/17:10236674 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27730/17:10236674
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mitigation of interferences between electric regulated drainage and track circuits
Popis výsledku v původním jazyce
Electric drainage is a device used to protect metal objects buried underground (usually pipelines or water supply) from electrochemical corrosion caused by DC stray currents. DC stray currents come from DC electric traction, such as electric railway or tramway. Electric drainage is a conductive connection between the rails and underground device, so current does not flow from the device into the ground (causing corrosion), but it flows through this connection instead. The most advanced type of electric drainage is regulated electric drainage, which usually uses pulse width modulation (PWM). This modulation creates current harmonic components with different frequencies. In railway tracks there are often track circuits, which use a certain frequency. For secure operation, it is necessary to make sure that frequencies generated by the drainage do not interfere with track circuits. This paper deals with the mitigation of interferences between regulated electric drainage and track circuits. It contains simulation results and also some measurement results acquired on a prototype installed on a tram track.
Název v anglickém jazyce
Mitigation of interferences between electric regulated drainage and track circuits
Popis výsledku anglicky
Electric drainage is a device used to protect metal objects buried underground (usually pipelines or water supply) from electrochemical corrosion caused by DC stray currents. DC stray currents come from DC electric traction, such as electric railway or tramway. Electric drainage is a conductive connection between the rails and underground device, so current does not flow from the device into the ground (causing corrosion), but it flows through this connection instead. The most advanced type of electric drainage is regulated electric drainage, which usually uses pulse width modulation (PWM). This modulation creates current harmonic components with different frequencies. In railway tracks there are often track circuits, which use a certain frequency. For secure operation, it is necessary to make sure that frequencies generated by the drainage do not interfere with track circuits. This paper deals with the mitigation of interferences between regulated electric drainage and track circuits. It contains simulation results and also some measurement results acquired on a prototype installed on a tram track.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 9th International Scientific Symposium on Electrical Power Engineering, ELEKTROENERGETIKA 2017
ISBN
978-80-553-3195-9
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
142-145
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
12. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce