Analysis of non-invasive FBG sensor for monitoring patient vital signs during MRI
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10237120" target="_blank" >RIV/61989100:27240/17:10237120 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85038437708&origin=resultslist&sort=plf-f&src=s&sid=afcf2f0227f5da9846eb8dd6a8a70cb5&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=17&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85038437708&origin=resultslist&sort=plf-f&src=s&sid=afcf2f0227f5da9846eb8dd6a8a70cb5&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=17&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2277399" target="_blank" >10.1117/12.2277399</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of non-invasive FBG sensor for monitoring patient vital signs during MRI
Popis výsledku v původním jazyce
This article focuses on the analysis and verification of a non-invasive fiber Bragg grating (FBG) sensor used for the monitoring of a patient's heart rate (HR) and respiratory rate (RR) in a magnetic resonance environment (MRI). Measuring heart and respiratory rate were carried out on a group of five volunteers with their written consent during MRI examinations. The type of the scanner used in the experiment was GE Signa HDxt 1.5T. The benefit of this article lies in the design of a sensor in the form of a sensor pad. The sensor is placed beneath a patient's body lying supine. The purpose is to increase and improve the patient's safety as well as to help doctors to predict panic and hyperventilation attacks of patients during MRI examinations. Provided Bland-Altman statistical analysis demonstrates the heart and respiratory rate detection with a satisfactory accuracy for all five volunteers.
Název v anglickém jazyce
Analysis of non-invasive FBG sensor for monitoring patient vital signs during MRI
Popis výsledku anglicky
This article focuses on the analysis and verification of a non-invasive fiber Bragg grating (FBG) sensor used for the monitoring of a patient's heart rate (HR) and respiratory rate (RR) in a magnetic resonance environment (MRI). Measuring heart and respiratory rate were carried out on a group of five volunteers with their written consent during MRI examinations. The type of the scanner used in the experiment was GE Signa HDxt 1.5T. The benefit of this article lies in the design of a sensor in the form of a sensor pad. The sensor is placed beneath a patient's body lying supine. The purpose is to increase and improve the patient's safety as well as to help doctors to predict panic and hyperventilation attacks of patients during MRI examinations. Provided Bland-Altman statistical analysis demonstrates the heart and respiratory rate detection with a satisfactory accuracy for all five volunteers.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.20.0217" target="_blank" >EE2.3.20.0217: Rozvoj excelence vědeckovýzkumného týmu Telekomunikační techniky ve vazbě na zahraniční spolupráci</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE - The International Society for Optical Engineering. Volume 10440
ISBN
978-1-5106-1344-7
ISSN
0277-786X
e-ISSN
neuvedeno
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Varšava
Datum konání akce
11. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—