Non-adaptive methods of fetal ecg signal processing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10238286" target="_blank" >RIV/61989100:27240/17:10238286 - isvavai.cz</a>
Výsledek na webu
<a href="http://advances.vsb.cz/index.php/AEEE/article/view/2196" target="_blank" >http://advances.vsb.cz/index.php/AEEE/article/view/2196</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15598/aeee.v15i3.2196" target="_blank" >10.15598/aeee.v15i3.2196</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Non-adaptive methods of fetal ecg signal processing
Popis výsledku v původním jazyce
Abdominal fetal ElectroCardioGrams (fECGs) carry a wealth of information about the fetus including fetal Heart Rate (fHR) and signal morphology during different stages of pregnancy. Here we report our results on the implementation and evaluation of two non-adaptive signal processing methods suitable for fECG signal extraction, namely: the Independent Component Analysis (ICA) and the Principal Component Analysis (PCA) Methods. We used the fetal heart rate extracted from fECG signals (in Beats Per Minute - BPM) and Signal-to-Noise Ratio (SNR) as effective performance evaluation metrics for our applied methods. Our findings demonstrated that given adequate SNR, these methods produced excellent results in accurate determination of fHR. Furthermore, we found out that compared to the PCA Method, the ICA Method produces a lower variance in the detection of the fHR. © 2017 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING.
Název v anglickém jazyce
Non-adaptive methods of fetal ecg signal processing
Popis výsledku anglicky
Abdominal fetal ElectroCardioGrams (fECGs) carry a wealth of information about the fetus including fetal Heart Rate (fHR) and signal morphology during different stages of pregnancy. Here we report our results on the implementation and evaluation of two non-adaptive signal processing methods suitable for fECG signal extraction, namely: the Independent Component Analysis (ICA) and the Principal Component Analysis (PCA) Methods. We used the fetal heart rate extracted from fECG signals (in Beats Per Minute - BPM) and Signal-to-Noise Ratio (SNR) as effective performance evaluation metrics for our applied methods. Our findings demonstrated that given adequate SNR, these methods produced excellent results in accurate determination of fHR. Furthermore, we found out that compared to the PCA Method, the ICA Method produces a lower variance in the detection of the fHR. © 2017 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advances in Electrical and Electronic Engineering
ISSN
1336-1376
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
15
Strana od-do
476-490
Kód UT WoS článku
000424330700012
EID výsledku v databázi Scopus
2-s2.0-85030541103