Danger of re-ingition of an electric arc in a resonant earthing medium voltage system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10238335" target="_blank" >RIV/61989100:27240/17:10238335 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Danger of re-ingition of an electric arc in a resonant earthing medium voltage system
Popis výsledku v původním jazyce
There are medium voltage networks which have a small extent from the point of capacity current (around 20 Amps). These systems can be operated as isolated neutral systems, resistor earthing systems or resonance earthing systems in numerous other modifications for such an extent of capacity current. The option which is currently enforced is one based on the resonance earthing system. The aim of this paper is to point out the danger of an arc earthing fault which can arise in resonance earthing medium voltage systems, particularly for the concrete specific extent of a medium voltage system and the corresponding capacity current in the areas of (5-20) Amps. For this specific system extent and earthing method there can be multiple re-ignitions during a fault current half-period and this makes it impossible to detect such a fault using (conventional) digital relay protection which works on the principle of fault current individual parts evaluation. This can only occur in the case that a fault arises.
Název v anglickém jazyce
Danger of re-ingition of an electric arc in a resonant earthing medium voltage system
Popis výsledku anglicky
There are medium voltage networks which have a small extent from the point of capacity current (around 20 Amps). These systems can be operated as isolated neutral systems, resistor earthing systems or resonance earthing systems in numerous other modifications for such an extent of capacity current. The option which is currently enforced is one based on the resonance earthing system. The aim of this paper is to point out the danger of an arc earthing fault which can arise in resonance earthing medium voltage systems, particularly for the concrete specific extent of a medium voltage system and the corresponding capacity current in the areas of (5-20) Amps. For this specific system extent and earthing method there can be multiple re-ignitions during a fault current half-period and this makes it impossible to detect such a fault using (conventional) digital relay protection which works on the principle of fault current individual parts evaluation. This can only occur in the case that a fault arises.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 9th International Scientific Symposium on Electrical Power Engineering, ELEKTROENERGETIKA 2017
ISBN
978-80-553-3195-9
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
7
Strana od-do
428-434
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
12. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—