The study is focused on the experimental research of the ambient light influence upon the blood perfusion measurement in the clinical conditions. The measurement reliability of the perfusion maps was performed on the base of Doppler method with using PeriScan PIM 3 device. The analysis leads to the list of standards and recommendations serving for the reliability improvement and the compactness of the blood perfusion measuring in the clinical conditions. The light conditions influence upon blood perfusion brings the optimization of diagnostic process and therapy as well. The blood perfusion influence was analyzed in the duplex scanning mode. The blood perfusion was statistically evaluated in the dependence of natural, fluorescent and operating light. Statistical evaluation consist linear regression representing prediction model of the blood perfusion in the dependence of a respective source of light. The important part of statistical analysis is 95% confidence intervals characterizing the estimated range of blood perfusion.
Název v anglickém jazyce
The light conditions influence upon blood perfusion in the duplex mode
Popis výsledku anglicky
The study is focused on the experimental research of the ambient light influence upon the blood perfusion measurement in the clinical conditions. The measurement reliability of the perfusion maps was performed on the base of Doppler method with using PeriScan PIM 3 device. The analysis leads to the list of standards and recommendations serving for the reliability improvement and the compactness of the blood perfusion measuring in the clinical conditions. The light conditions influence upon blood perfusion brings the optimization of diagnostic process and therapy as well. The blood perfusion influence was analyzed in the duplex scanning mode. The blood perfusion was statistically evaluated in the dependence of natural, fluorescent and operating light. Statistical evaluation consist linear regression representing prediction model of the blood perfusion in the dependence of a respective source of light. The important part of statistical analysis is 95% confidence intervals characterizing the estimated range of blood perfusion.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Engineering and Applied Sciences
ISSN
1816-949X
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
Specialissue3
Stát vydavatele periodika
PK - Pákistánská islámská republika
Počet stran výsledku
5
Strana od-do
3221-3225
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85049911628