Behavior of electricity meters and quality analyzers using equipment to optimize subscriptions in small photovoltaic power plants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F19%3A10243093" target="_blank" >RIV/61989100:27240/19:10243093 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Behavior of electricity meters and quality analyzers using equipment to optimize subscriptions in small photovoltaic power plants
Popis výsledku v původním jazyce
There are currently many users of photovoltaic power plants that have devices to optimize their consumption or supply of electricity. These devices use the aggregation interval lengths to measure the electricity meter to redistribute the energy flow so that the balance is zero at this time. The electricity meters are unable to record these fast changes in the direction of the power flow, but the modified quality analyzers do. Therefore, tests were performed to simulate the different algorithms used by these optimization devices. In the laboratory, the behavior of electricity meters and modified quality analyzers in the measurement of the test progress was tested. The result is a comparison of the calculated values of the energy consumed and delivered, over time, for all devices tested. (C) Technical University of Košice 2019.
Název v anglickém jazyce
Behavior of electricity meters and quality analyzers using equipment to optimize subscriptions in small photovoltaic power plants
Popis výsledku anglicky
There are currently many users of photovoltaic power plants that have devices to optimize their consumption or supply of electricity. These devices use the aggregation interval lengths to measure the electricity meter to redistribute the energy flow so that the balance is zero at this time. The electricity meters are unable to record these fast changes in the direction of the power flow, but the modified quality analyzers do. Therefore, tests were performed to simulate the different algorithms used by these optimization devices. In the laboratory, the behavior of electricity meters and modified quality analyzers in the measurement of the test progress was tested. The result is a comparison of the calculated values of the energy consumed and delivered, over time, for all devices tested. (C) Technical University of Košice 2019.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 10th International Scientific Symposium on Electrical Power Engineering, ELEKTROENERGETIKA 2019
ISBN
978-80-553-3324-3
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
92-96
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
16. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—