FEM Models of Rotor Failures in Comparison to Real Measurement of IM by External Stray Field
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F19%3A10244221" target="_blank" >RIV/61989100:27240/19:10244221 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8778119" target="_blank" >https://ieeexplore.ieee.org/document/8778119</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2019.8778119" target="_blank" >10.1109/EPE.2019.8778119</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
FEM Models of Rotor Failures in Comparison to Real Measurement of IM by External Stray Field
Popis výsledku v původním jazyce
The paper deals with the validation of the 2D FEM model of induction motor with rotor failures. Output results of FEM analysis are compared to the real laboratory measurement of asynchronous motor. External magnetic stray field is used like the basic diagnostic method of it. The main parameter to be analyzed is the induced voltage generated on the coil, which senses the external stray field in radial direction of motor axis. Fast Fourier Transformation is used to evaluate the individual components of the voltage spectrum according to common diagnostic procedures. 2D FEM model of asynchronous motor has the same parameters of real motor in laboratory including nominal output power, rpm, power factor, voltage and current. Irreversible machine failures are created with adjustment of rotor bar by drilling or in case of eccentricity by misaligned setting in bearings.
Název v anglickém jazyce
FEM Models of Rotor Failures in Comparison to Real Measurement of IM by External Stray Field
Popis výsledku anglicky
The paper deals with the validation of the 2D FEM model of induction motor with rotor failures. Output results of FEM analysis are compared to the real laboratory measurement of asynchronous motor. External magnetic stray field is used like the basic diagnostic method of it. The main parameter to be analyzed is the induced voltage generated on the coil, which senses the external stray field in radial direction of motor axis. Fast Fourier Transformation is used to evaluate the individual components of the voltage spectrum according to common diagnostic procedures. 2D FEM model of asynchronous motor has the same parameters of real motor in laboratory including nominal output power, rpm, power factor, voltage and current. Irreversible machine failures are created with adjustment of rotor bar by drilling or in case of eccentricity by misaligned setting in bearings.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2019 20th International Scientific Conference on Electric Power Engineering, EPE 2019
ISBN
978-1-72811-333-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
107-112
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Kouty nad Desnou
Datum konání akce
15. 5. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000535890900023