New design and improvements of an MR-compatible respiratory fiber-optic sensor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F23%3A10254582" target="_blank" >RIV/61989100:27240/23:10254582 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85170639227&origin=resultslist" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85170639227&origin=resultslist</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2669707" target="_blank" >10.1117/12.2669707</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New design and improvements of an MR-compatible respiratory fiber-optic sensor
Popis výsledku v původním jazyce
The article describes a modification of the fiber-optic sensor based on a Bragg grating, which is implemented in oxygen glasses, which are commonly used in real medical practice. This type of experimental fiber-optic sensor can be used to monitor the respiratory activity of the human body over time. Modifications primarily consist of the design improvement of the Bragg grating implementation itself in using conventional oxygen glasses for better transfer of measured parameters to the Bragg grating itself. The practical part also describes the experimental verification of the functionality and the subsequent evaluation of the measured data. The experimental measurement was carried out on a group of 5 volunteers in laboratory conditions.
Název v anglickém jazyce
New design and improvements of an MR-compatible respiratory fiber-optic sensor
Popis výsledku anglicky
The article describes a modification of the fiber-optic sensor based on a Bragg grating, which is implemented in oxygen glasses, which are commonly used in real medical practice. This type of experimental fiber-optic sensor can be used to monitor the respiratory activity of the human body over time. Modifications primarily consist of the design improvement of the Bragg grating implementation itself in using conventional oxygen glasses for better transfer of measured parameters to the Bragg grating itself. The practical part also describes the experimental verification of the functionality and the subsequent evaluation of the measured data. The experimental measurement was carried out on a group of 5 volunteers in laboratory conditions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE - The International Society for Optical Engineering. Volume 12572
ISBN
978-1-5106-6264-3
ISSN
0277-786X
e-ISSN
1996-756X
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
SPIE-The International Society for Optical Engineering
Místo vydání
Bellingham
Místo konání akce
Praha
Datum konání akce
24. 4. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—