Popis výsledku v původním jazyce
Testing at very low frequencies (typically 0,1 Hz and less) represents an alternative to DC, 50 or 60 Hz hipot tests. It is standardized and up-to date method for medium voltage cable condition assessment. VLF tests can be also used for partial discharge detection and measurement. Unlike the partial discharge detection at power grid frequency, partial discharges at VLF testing have different characteristics and parameters. Furthermore, the possibility of partial discharge detection in various frequency ranges makes the situation even more complicated. Various frequency ranges sometimes provide various results from a single device under the test.
Název v anglickém jazyce
The Influence of Frequency Range on VLF Partial Discharge measurement
Popis výsledku anglicky
Testing at very low frequencies (typically 0,1 Hz and less) represents an alternative to DC, 50 or 60 Hz hipot tests. It is standardized and up-to date method for medium voltage cable condition assessment. VLF tests can be also used for partial discharge detection and measurement. Unlike the partial discharge detection at power grid frequency, partial discharges at VLF testing have different characteristics and parameters. Furthermore, the possibility of partial discharge detection in various frequency ranges makes the situation even more complicated. Various frequency ranges sometimes provide various results from a single device under the test.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TN02000025" target="_blank" >TN02000025: Národní centrum pro energetiku II</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Diagnostika 2024 : 2024 International Conference on Diagnostics in Electrical Engineering : conference proceedings
ISBN
979-8-3503-6150-6
ISSN
—
e-ISSN
2464-708X
Počet stran výsledku
5
Strana od-do
90-94
Název nakladatele
IEEE
Místo vydání
Vienna
Místo konání akce
Pilsen
Datum konání akce
3. 9. 2024