A novel TID plus IDN controller tuned with coatis optimization algorithm under deregulated hybrid power system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F25%3A10257442" target="_blank" >RIV/61989100:27240/25:10257442 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27730/25:10257442
Výsledek na webu
<a href="https://www.nature.com/articles/s41598-025-89025-w" target="_blank" >https://www.nature.com/articles/s41598-025-89025-w</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-025-89237-0" target="_blank" >10.1038/s41598-025-89237-0</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A novel TID plus IDN controller tuned with coatis optimization algorithm under deregulated hybrid power system
Popis výsledku v původním jazyce
Implementing a suitable load frequency controller to maintain the power balance equation for a multi-area system with many power generating units poses a challenge to a power system engineer. Incorporation of renewable energy sources along with non-renewable units is another challenge while maintaining the stability of the system. Hence a robust intelligent controller is an essential requirement to achieve the objective of automatic load frequency control. This article introduces a novel and efficient controller designed for a three-control area within a deregulated multi-source energy system. The three areas include diverse power generation sources: Area 1 integrates thermal units, hydro units, and solar thermal power plants. In Area 2, there is a combination of distributed solar technology (DST) with thermal and hydro units. Area 3 incorporates a geothermal power plant alongside thermal and hydro unit. The proposed controller is a parallel combination of the tilted integral derivative controller (TID) and the integral derivative with a first-order filter effect (IDN). The controller's parameters are optimized using an advanced Coatis Optimization Algorithm (COA). High effective efficiency and absence of control parameters are the key advantages of Coatis Optimization Algorithm. The article highlights the superior performance of the newly developed TID + IDN controller in comparison to standalone TID and IDN controllers. This assessment is based on the observation of dynamic responses across different controller configurations. Additionally, the study examines the system's behaviour when incorporating energy storage units such as Redox Flow Batteries (RFB). Furthermore, the research investigates the system under various power transactions in a deregulated environment, considering generation rate constraints and governor dead bands. The proposed approach's robustness is demonstrated by subjecting it to extensive variations in system parameters and random load fluctuations. In summary, this paper presents an innovative TID + IDN controller optimized using a novel Coatis Optimization Algorithm within a three-area hybrid system operating in a deregulated context. Considering the poolco transaction and implementing the COA optimized TID + IDN controller with an error margin of 0.02%, the value of the objective function, ITAE for the transient responses is 0.1233. This value is less than the value obtained in other controllers optimized with different optimization techniques. In case of poolco transaction, the settling time of deviation of frequency in area-1, deviation of frequency in area-2, and deviation of frequency in area-3 are 8.129, 3.72, and 2.254 respectively. As compared to other controllers, the transient parameters are better in case of this proposed controller.
Název v anglickém jazyce
A novel TID plus IDN controller tuned with coatis optimization algorithm under deregulated hybrid power system
Popis výsledku anglicky
Implementing a suitable load frequency controller to maintain the power balance equation for a multi-area system with many power generating units poses a challenge to a power system engineer. Incorporation of renewable energy sources along with non-renewable units is another challenge while maintaining the stability of the system. Hence a robust intelligent controller is an essential requirement to achieve the objective of automatic load frequency control. This article introduces a novel and efficient controller designed for a three-control area within a deregulated multi-source energy system. The three areas include diverse power generation sources: Area 1 integrates thermal units, hydro units, and solar thermal power plants. In Area 2, there is a combination of distributed solar technology (DST) with thermal and hydro units. Area 3 incorporates a geothermal power plant alongside thermal and hydro unit. The proposed controller is a parallel combination of the tilted integral derivative controller (TID) and the integral derivative with a first-order filter effect (IDN). The controller's parameters are optimized using an advanced Coatis Optimization Algorithm (COA). High effective efficiency and absence of control parameters are the key advantages of Coatis Optimization Algorithm. The article highlights the superior performance of the newly developed TID + IDN controller in comparison to standalone TID and IDN controllers. This assessment is based on the observation of dynamic responses across different controller configurations. Additionally, the study examines the system's behaviour when incorporating energy storage units such as Redox Flow Batteries (RFB). Furthermore, the research investigates the system under various power transactions in a deregulated environment, considering generation rate constraints and governor dead bands. The proposed approach's robustness is demonstrated by subjecting it to extensive variations in system parameters and random load fluctuations. In summary, this paper presents an innovative TID + IDN controller optimized using a novel Coatis Optimization Algorithm within a three-area hybrid system operating in a deregulated context. Considering the poolco transaction and implementing the COA optimized TID + IDN controller with an error margin of 0.02%, the value of the objective function, ITAE for the transient responses is 0.1233. This value is less than the value obtained in other controllers optimized with different optimization techniques. In case of poolco transaction, the settling time of deviation of frequency in area-1, deviation of frequency in area-2, and deviation of frequency in area-3 are 8.129, 3.72, and 2.254 respectively. As compared to other controllers, the transient parameters are better in case of this proposed controller.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TN02000025" target="_blank" >TN02000025: Národní centrum pro energetiku II</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
2045-2322
Svazek periodika
15
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
31
Strana od-do
nestránkováno
Kód UT WoS článku
001417014400032
EID výsledku v databázi Scopus
—