Effect of column bleed on trueness of high resolution mass spectrometric determination of dibenzo-p-dioxins, dibenzofuranes and polychlorinated biphenyls
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27350%2F14%3A86082334" target="_blank" >RIV/61989100:27350/14:86082334 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1556/AChrom.26.2014.2.11" target="_blank" >http://dx.doi.org/10.1556/AChrom.26.2014.2.11</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1556/AChrom.26.2014.2.11" target="_blank" >10.1556/AChrom.26.2014.2.11</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of column bleed on trueness of high resolution mass spectrometric determination of dibenzo-p-dioxins, dibenzofuranes and polychlorinated biphenyls
Popis výsledku v původním jazyce
Effect of column bleed on trueness of determination of trace levels of PCDD/F and PCB by GC/HRMS was studied. As a result of extensive bleed of an arylene-siloxane capillary column, fluctuations of abundance ratios of monitored ions were observed, makingexact determination of target analytes impossible. These effects were observed on food samples as well as on pure standard mixtures. The column bleed affected the abundance ratios of PCDD/F and PCB within the range of 13 ? 328 pg of target analyte/ml ,higher levels of analytes remained intact. An analysis of diluted calibration mixtures is recommended as a tool for detection of column bleed.
Název v anglickém jazyce
Effect of column bleed on trueness of high resolution mass spectrometric determination of dibenzo-p-dioxins, dibenzofuranes and polychlorinated biphenyls
Popis výsledku anglicky
Effect of column bleed on trueness of determination of trace levels of PCDD/F and PCB by GC/HRMS was studied. As a result of extensive bleed of an arylene-siloxane capillary column, fluctuations of abundance ratios of monitored ions were observed, makingexact determination of target analytes impossible. These effects were observed on food samples as well as on pure standard mixtures. The column bleed affected the abundance ratios of PCDD/F and PCB within the range of 13 ? 328 pg of target analyte/ml ,higher levels of analytes remained intact. An analysis of diluted calibration mixtures is recommended as a tool for detection of column bleed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0082" target="_blank" >ED2.1.00/03.0082: Institut čistých technologií těžby a užití energetických surovin</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Chromatographica
ISSN
1233-2356
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
8
Strana od-do
347-354
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—