Frost resistance of cement composites prepared on the basis of waste water from a concrete plant
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27350%2F18%3A10240421" target="_blank" >RIV/61989100:27350/18:10240421 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1515/sspjce-2018-0026" target="_blank" >http://dx.doi.org/10.1515/sspjce-2018-0026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/sspjce-2018-0026" target="_blank" >10.1515/sspjce-2018-0026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Frost resistance of cement composites prepared on the basis of waste water from a concrete plant
Popis výsledku v původním jazyce
This article presents the results of a research dealing with the use of waste water from concrete industry as a possible substitution of mixing water during the production of cement composites. This experimental research involved the preparation of two recipes of cement composites, named R1 and R3. Mixing water in these recipes was replaced with waste water from a concrete plant in the amount of 25, 50, 75 and 100%. Samples of recycled waste water, which were tested for the content of sulphates, chlorides and alkali according to ČSN EN 1008, were taken in order to determine the properties of waste water from a concrete plant. The prepared test specimens were tested for frost resistance after 100 freezing cycles according to ČSN 73 1322. The results of the frost resistance test showed that the required value of the frost resistance coefficient of 0.75 according to ČSN 73 1322 was achieved only in case of recipe R1 based on Portland cement CEM I 52.5R and 75 and 100% substitution of the mixing water with recycled water from a concrete plant.
Název v anglickém jazyce
Frost resistance of cement composites prepared on the basis of waste water from a concrete plant
Popis výsledku anglicky
This article presents the results of a research dealing with the use of waste water from concrete industry as a possible substitution of mixing water during the production of cement composites. This experimental research involved the preparation of two recipes of cement composites, named R1 and R3. Mixing water in these recipes was replaced with waste water from a concrete plant in the amount of 25, 50, 75 and 100%. Samples of recycled waste water, which were tested for the content of sulphates, chlorides and alkali according to ČSN EN 1008, were taken in order to determine the properties of waste water from a concrete plant. The prepared test specimens were tested for frost resistance after 100 freezing cycles according to ČSN 73 1322. The results of the frost resistance test showed that the required value of the frost resistance coefficient of 0.75 according to ČSN 73 1322 was achieved only in case of recipe R1 based on Portland cement CEM I 52.5R and 75 and 100% substitution of the mixing water with recycled water from a concrete plant.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20505 - Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics; filled composites)
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1406" target="_blank" >LO1406: Institut čistých technologií těžby a užití energetických surovin - Projekt udržitelnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Selected Scientific Papers - Journal of Civil Engineering
ISSN
1338-9024
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—