The electrochemical potentiokinetic reactivation method - the procedure of the double loop (DL EPR) is standardized for evaluation of the intergranular corrosion susceptibility of common stainless steels. Two nickel base alloys (Alloy 825 and 59 were tested by the DL EPR method to prove the intergranular corrosion susceptibility. All samples of these alloys were submitted to: 1) sensitization annealing at selected temperatures (590-750°C) and time. 2) Simulation of heat affected zone at weld. The susceptibility to intergranular corrosion was evaluated by the standard corrosion tests and by the structure changes and corrosion penetration observations using microscopy. At the optimal conditions the results obtained by the DL EPR method are relatively compatible with the results of other performed tests. The testing conditions of usual DL EPR had to be modified for testing of stainless metallic materials of higher corrosion resistance.
Název v anglickém jazyce
Electrochemical polarization potentiokinetic reactivation method - epr test - for the high alloyed stainless materials.
Popis výsledku anglicky
The electrochemical potentiokinetic reactivation method - the procedure of the double loop (DL EPR) is standardized for evaluation of the intergranular corrosion susceptibility of common stainless steels. Two nickel base alloys (Alloy 825 and 59 were tested by the DL EPR method to prove the intergranular corrosion susceptibility. All samples of these alloys were submitted to: 1) sensitization annealing at selected temperatures (590-750°C) and time. 2) Simulation of heat affected zone at weld. The susceptibility to intergranular corrosion was evaluated by the standard corrosion tests and by the structure changes and corrosion penetration observations using microscopy. At the optimal conditions the results obtained by the DL EPR method are relatively compatible with the results of other performed tests. The testing conditions of usual DL EPR had to be modified for testing of stainless metallic materials of higher corrosion resistance.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JK - Koroze a povrchové úpravy materiálu
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F98%2F0182" target="_blank" >GA106/98/0182: Výzkum elektrochemické polarizační potenciokinetické reaktivační metody (EPR) pro kontrolu vysokolegovaných korozivzdorných materiálů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
23rd European Corrosion Congress
ISBN
1-86125-127-0
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
WINN and COALES,DEN SO LTD, London
Místo vydání
London, GB
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—