Biotic Attack in Claddings of Prefabricated Buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F13%3A86087404" target="_blank" >RIV/61989100:27360/13:86087404 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27120/13:86087404
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.372.189" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMM.372.189</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.372.189" target="_blank" >10.4028/www.scientific.net/AMM.372.189</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biotic Attack in Claddings of Prefabricated Buildings
Popis výsledku v původním jazyce
Problems biotic attack facades of prefabricated buildings takes particular with regard to given increasing demands and requirements of thermal technique and energy. In the last twenty years, increased demands on thermal properties of exterior walls, increasing the thickness of thermal insulation, additional insulation contact changes prefabricated walls on multilayer circuit design, but at the same time claddings prefab evident adverse side effects in the form of color change in outer surface renderinglocally and globally. In this paper are discussed laboratory tests on the sample confirmed the presence of external plaster façade panel biotic attach building, which is equipped with additional contact system.
Název v anglickém jazyce
Biotic Attack in Claddings of Prefabricated Buildings
Popis výsledku anglicky
Problems biotic attack facades of prefabricated buildings takes particular with regard to given increasing demands and requirements of thermal technique and energy. In the last twenty years, increased demands on thermal properties of exterior walls, increasing the thickness of thermal insulation, additional insulation contact changes prefabricated walls on multilayer circuit design, but at the same time claddings prefab evident adverse side effects in the form of color change in outer surface renderinglocally and globally. In this paper are discussed laboratory tests on the sample confirmed the presence of external plaster façade panel biotic attach building, which is equipped with additional contact system.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Applied Mechanics and Materials. Volume 372
ISBN
978-3-03785-797-7
ISSN
1660-9336
e-ISSN
—
Počet stran výsledku
6
Strana od-do
189-194
Název nakladatele
Trans Tech Publications
Místo vydání
Durnten-Zurich
Místo konání akce
Kuala Lumpur
Datum konání akce
17. 5. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—