Influence of experimental conditions on data obtained by thermal analysis methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F13%3A86087826" target="_blank" >RIV/61989100:27360/13:86087826 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of experimental conditions on data obtained by thermal analysis methods
Popis výsledku v původním jazyce
Differential thermal analysis (DTA) and Differential Scanning Calorimetry (DSC) are two of the methods that are suitable for obtaining thermo-physical and thermo-dynamical data. This paper deals with the influence of the experimental conditions settingsof the used DTA and DSC methods in relation to the obtained data. The paper is focused on the study of heating/cooling rate and mass influence of the sample on shifting of the phase transformations temperatures and size of the thermal effects of alpha-gamma, gamma-delta phase transformations and melting of ?pure Fe?. Sample mass and heating/cooling rate belong to the frequently and easily changing parameters and their influence on the obtained data is substantial. The study was aimed both at low temperature and high temperature regions. DTA measurements were realised using the Setaram Setsys 18TM laboratory system, and DSC measurements using the Setaram MHTC laboratory system. The samples of ?pure Fe? (with different mass) were analysed
Název v anglickém jazyce
Influence of experimental conditions on data obtained by thermal analysis methods
Popis výsledku anglicky
Differential thermal analysis (DTA) and Differential Scanning Calorimetry (DSC) are two of the methods that are suitable for obtaining thermo-physical and thermo-dynamical data. This paper deals with the influence of the experimental conditions settingsof the used DTA and DSC methods in relation to the obtained data. The paper is focused on the study of heating/cooling rate and mass influence of the sample on shifting of the phase transformations temperatures and size of the thermal effects of alpha-gamma, gamma-delta phase transformations and melting of ?pure Fe?. Sample mass and heating/cooling rate belong to the frequently and easily changing parameters and their influence on the obtained data is substantial. The study was aimed both at low temperature and high temperature regions. DTA measurements were realised using the Setaram Setsys 18TM laboratory system, and DSC measurements using the Setaram MHTC laboratory system. The samples of ?pure Fe? (with different mass) were analysed
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
METAL 2013 : 22nd International Conference on Metallurgy and Materials : conference proceedings : May 15th - 17th 2013, Hotel Voronez I, Brno Czech Republic, EU [CD-ROM]
ISBN
978-80-87294-41-3
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
585-591
Název nakladatele
Tanger
Místo vydání
Ostrava
Místo konání akce
Brno
Datum konání akce
15. 5. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce