Heat Loading of Steam Boilers Heating Surfaces
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F17%3A10236711" target="_blank" >RIV/61989100:27360/17:10236711 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016796488&partnerID=40&md5=543a87b9df2412777e80cbace812d456" target="_blank" >https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016796488&partnerID=40&md5=543a87b9df2412777e80cbace812d456</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Heat Loading of Steam Boilers Heating Surfaces
Popis výsledku v původním jazyce
This paper deals with the comparison of an analytical solution of the temperature field of a steam boiler pipe membrane wall using a numerical method calculation in the COSMOS/M programme. The result analysis showed that analytical calculating methods which are limited to 1D and 2D task types can be used for the approximate calculation of temperature in the selected locations of the membrane wall. With these methods it is not possible to obtain a complex view of the heat loading of the entire membrane wall or of the stress conditions caused by the thermal and pressure effect of steam-water mixture in the wall pipes. The results of numerical simulations have provided a complex image about the temperature and pressure distribution in the entire membrane wall of a steam boiler taking into account the material properties
Název v anglickém jazyce
Heat Loading of Steam Boilers Heating Surfaces
Popis výsledku anglicky
This paper deals with the comparison of an analytical solution of the temperature field of a steam boiler pipe membrane wall using a numerical method calculation in the COSMOS/M programme. The result analysis showed that analytical calculating methods which are limited to 1D and 2D task types can be used for the approximate calculation of temperature in the selected locations of the membrane wall. With these methods it is not possible to obtain a complex view of the heat loading of the entire membrane wall or of the stress conditions caused by the thermal and pressure effect of steam-water mixture in the wall pipes. The results of numerical simulations have provided a complex image about the temperature and pressure distribution in the entire membrane wall of a steam boiler taking into account the material properties
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20500 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
157-163
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85016796488