Popis výsledku v původním jazyce
In this proceeding, we present a software Fit@TDS that enables to retrieve the refractive index of a sample from a time-domain spectroscopy experiment. The software include commonly used methods where the refractive index is extracted from frequency domain data. This method has limitations when the signal is too noisy or when the absorption peak saturates the absorption. Thus, the software includes as well a new method where the refractive index are directly fitted using a model (the Drude-Lorentz for example) in the time domain. This method uses an optimization algorithm that retrieves the parameters of the model corresponding to the studied material. In this proceeding, we explain the methods and test them on fictitious samples to probe the feasibility and reliability of the proposed model.
Název v anglickém jazyce
Modeling and parameter retrieving in time domain spectroscopy of material and metamaterial
Popis výsledku anglicky
In this proceeding, we present a software Fit@TDS that enables to retrieve the refractive index of a sample from a time-domain spectroscopy experiment. The software include commonly used methods where the refractive index is extracted from frequency domain data. This method has limitations when the signal is too noisy or when the absorption peak saturates the absorption. Thus, the software includes as well a new method where the refractive index are directly fitted using a model (the Drude-Lorentz for example) in the time domain. This method uses an optimization algorithm that retrieves the parameters of the model corresponding to the studied material. In this proceeding, we explain the methods and test them on fictitious samples to probe the feasibility and reliability of the proposed model.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE - The International Society for Optical Engineering. Volume 10684
ISBN
978-1-5106-1895-4
ISSN
0277-786X
e-ISSN
1996-756X
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
SPIE - The International Society for Optical Engineering
Místo vydání
Bellingham
Místo konání akce
Strasbourg
Datum konání akce
23. 4. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000442070600005