Measurement of Thermal Conductivity of Sludge and Liquid Materials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F18%3A10240874" target="_blank" >RIV/61989100:27360/18:10240874 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1051/matecconf/201816801001" target="_blank" >http://dx.doi.org/10.1051/matecconf/201816801001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/matecconf/201816801001" target="_blank" >10.1051/matecconf/201816801001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Thermal Conductivity of Sludge and Liquid Materials
Popis výsledku v původním jazyce
The present article describes two various methods of determination of thermal conductivity of semi-solid and liquid materials. One is based on experimental measurements of heat flux through a layer of semi-solid material while using the Heat Flow Plates, and the second one uses Peltier Elements to determine the heat flux density. The first method was used to determine thermal conductivity of sludge taken from natural gas coolers. Its value, identified by measurements, was 0.746 W.m-1.K-1. The second method was applied to determine thermal conductivity for sludge taken from natural gas filtration units. Values thereof were ranging from 0.608 W.m-1.K-1 (at the mean sludge temperature of 22 oC) to 0.652 W.m-1.K-1 (at the sludge temperature of 43 oC). (C) 2018 The Authors, published by EDP Sciences.
Název v anglickém jazyce
Measurement of Thermal Conductivity of Sludge and Liquid Materials
Popis výsledku anglicky
The present article describes two various methods of determination of thermal conductivity of semi-solid and liquid materials. One is based on experimental measurements of heat flux through a layer of semi-solid material while using the Heat Flow Plates, and the second one uses Peltier Elements to determine the heat flux density. The first method was used to determine thermal conductivity of sludge taken from natural gas coolers. Its value, identified by measurements, was 0.746 W.m-1.K-1. The second method was applied to determine thermal conductivity for sludge taken from natural gas filtration units. Values thereof were ranging from 0.608 W.m-1.K-1 (at the mean sludge temperature of 22 oC) to 0.652 W.m-1.K-1 (at the sludge temperature of 43 oC). (C) 2018 The Authors, published by EDP Sciences.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů