Optimization of experimental conditions for Fe-C-O-X (X=Cr, Ni) based systems by DTA method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F19%3A10242913" target="_blank" >RIV/61989100:27360/19:10242913 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimization of experimental conditions for Fe-C-O-X (X=Cr, Ni) based systems by DTA method
Popis výsledku v původním jazyce
One model alloy based on Fe-C-Cr and one model alloy based on Fe-C-Ni were studied. Fe-C-Cr based alloy contained carbon of 0.34 wt. % and chromium of 0.92 wt. %. Fe-C-Ni based alloy contained carbon of 0.38 wt. % and nickel of 1.08 wt. %. Temperatures of phase transformations (temperature of the solidus, liquidus and peritectic transformation) were studied in the high-temperature area by a heating rate of 1, 2, 5, 10 and 20oC/min., the influence of heating rate was investigated. The influence of the sample mass was also studied by the heating rate of 10oC/min. Samples with mass 50, 100, 190, 280 and 370 mg were studied. Samples with the mass 190 mg were studied by various heating rates. The Setaram Setsys 18TM device was used for experiments with the use of the DTA method. No influence of the heating rate was detected for the temperature of solidus for both alloys. The most significant influence of heating rate was observed for the temperature of liquidus.
Název v anglickém jazyce
Optimization of experimental conditions for Fe-C-O-X (X=Cr, Ni) based systems by DTA method
Popis výsledku anglicky
One model alloy based on Fe-C-Cr and one model alloy based on Fe-C-Ni were studied. Fe-C-Cr based alloy contained carbon of 0.34 wt. % and chromium of 0.92 wt. %. Fe-C-Ni based alloy contained carbon of 0.38 wt. % and nickel of 1.08 wt. %. Temperatures of phase transformations (temperature of the solidus, liquidus and peritectic transformation) were studied in the high-temperature area by a heating rate of 1, 2, 5, 10 and 20oC/min., the influence of heating rate was investigated. The influence of the sample mass was also studied by the heating rate of 10oC/min. Samples with mass 50, 100, 190, 280 and 370 mg were studied. Samples with the mass 190 mg were studied by various heating rates. The Setaram Setsys 18TM device was used for experiments with the use of the DTA method. No influence of the heating rate was detected for the temperature of solidus for both alloys. The most significant influence of heating rate was observed for the temperature of liquidus.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-18668S" target="_blank" >GA17-18668S: Komplexní experimentální výzkum vybraných vlastností kvaternárních a quinárních systémů Fe-C-O-X(Y), (X,Y=Cr,Ni) za vysokých teplot</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů