Dual-Resonance Split Ring Resonator Metasurface for Terahertz Biosensing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F24%3A10255652" target="_blank" >RIV/61989100:27360/24:10255652 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10474307" target="_blank" >https://ieeexplore.ieee.org/document/10474307</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/JSEN.2024.3376290" target="_blank" >10.1109/JSEN.2024.3376290</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dual-Resonance Split Ring Resonator Metasurface for Terahertz Biosensing
Popis výsledku v původním jazyce
In this article, the 'terahertz gap' has been addressed by designing a novel THz metasurface for potential use in biosensing applications. The metasurface sensor employs surface plasmon resonance (SPR). It operates in the 0-1 THz band. Two sharp reflection dips are provided by the sensor, which serve as indicators of analyte refractive index variations. Geometrical as well as compositional parameters of the biosensor design have been studied to optimize the performance in the targeted frequency band. The sensor design shows compatibility with different metals. The performance of the metasurface with gold, copper, and aluminum has been investigated. The metasurface geometry is decently resilient to fabrication tolerances. The sensor maintains its resonance conditions when the angle of incidence is changed with minor deviations in the spectral response, but the polarization state of the incident terahertz beam clearly disturbs the absorption peak. Therefore, the sensing performance is restricted to a maximum allowable incidence angle of 20. and circularly polarized terahertz beams. The resonance conditions for the metasurface appear around 0.4 and 0.7 THz. Both resonances have been investigated with respect to changes in the analyte refractive index. The chosen refractive index range is 1 to 1.5. The sensor response is calibrated by plotting the resonance frequency versus the refractive index. Least squares regression technique has been used to extract a data model for sensor response. Comparison of the proposed design with contemporary works has been incorporated into the article. The sensor provides sensitivities of 0.1614 and 0.23 THz/RIU. The electromagnetic simulations have been carried out through the finite element method (FEM).
Název v anglickém jazyce
Dual-Resonance Split Ring Resonator Metasurface for Terahertz Biosensing
Popis výsledku anglicky
In this article, the 'terahertz gap' has been addressed by designing a novel THz metasurface for potential use in biosensing applications. The metasurface sensor employs surface plasmon resonance (SPR). It operates in the 0-1 THz band. Two sharp reflection dips are provided by the sensor, which serve as indicators of analyte refractive index variations. Geometrical as well as compositional parameters of the biosensor design have been studied to optimize the performance in the targeted frequency band. The sensor design shows compatibility with different metals. The performance of the metasurface with gold, copper, and aluminum has been investigated. The metasurface geometry is decently resilient to fabrication tolerances. The sensor maintains its resonance conditions when the angle of incidence is changed with minor deviations in the spectral response, but the polarization state of the incident terahertz beam clearly disturbs the absorption peak. Therefore, the sensing performance is restricted to a maximum allowable incidence angle of 20. and circularly polarized terahertz beams. The resonance conditions for the metasurface appear around 0.4 and 0.7 THz. Both resonances have been investigated with respect to changes in the analyte refractive index. The chosen refractive index range is 1 to 1.5. The sensor response is calibrated by plotting the resonance frequency versus the refractive index. Least squares regression technique has been used to extract a data model for sensor response. Comparison of the proposed design with contemporary works has been incorporated into the article. The sensor provides sensitivities of 0.1614 and 0.23 THz/RIU. The electromagnetic simulations have been carried out through the finite element method (FEM).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10300 - Physical sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/EH22_008%2F0004631" target="_blank" >EH22_008/0004631: Materiály a technologie pro udržitelný rozvoj</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Sensors Journal
ISSN
1530-437X
e-ISSN
1558-1748
Svazek periodika
24
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
14189-14196
Kód UT WoS článku
001219652600052
EID výsledku v databázi Scopus
2-s2.0-85188522182