Genotoxicita pyrometalurgických odpadních materiálů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27640%2F07%3A00015150" target="_blank" >RIV/61989100:27640/07:00015150 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Genotoxicity of pyrometallurgical waste materials
Popis výsledku v původním jazyce
Waste materials sampled from electrofilters and wet scrubbers purificating waste gases coming out from pyrometallurgical plants: oxygen converter (OC), open-hearth furnace (OHF), blast furnace (BF), and electric arc furnace (EAF) were investigated in term of of PAHs content and mutagenic potency. Mutagenicity of extractable organic mass was assessed by using two detection systems the SOS Chromotest and the Ames test with Salmonella typhimurium bacterial strain. Both tests were performed without and withmetabolic activation by addition of rat liver enzymes. The highest mutagenicity after the activation was observed for the OC sludge. Nonetheless, other samples were potentially mutagenic as well. The bioassays without activation revealed no mutagenicity, thus we can assume that these samples do not contain any direct mutagens. However, they pose risk to higher organisms in which metabolic PAHs conversion occurs.
Název v anglickém jazyce
Genotoxicity of pyrometallurgical waste materials
Popis výsledku anglicky
Waste materials sampled from electrofilters and wet scrubbers purificating waste gases coming out from pyrometallurgical plants: oxygen converter (OC), open-hearth furnace (OHF), blast furnace (BF), and electric arc furnace (EAF) were investigated in term of of PAHs content and mutagenic potency. Mutagenicity of extractable organic mass was assessed by using two detection systems the SOS Chromotest and the Ames test with Salmonella typhimurium bacterial strain. Both tests were performed without and withmetabolic activation by addition of rat liver enzymes. The highest mutagenicity after the activation was observed for the OC sludge. Nonetheless, other samples were potentially mutagenic as well. The bioassays without activation revealed no mutagenicity, thus we can assume that these samples do not contain any direct mutagens. However, they pose risk to higher organisms in which metabolic PAHs conversion occurs.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DM - Tuhý odpad a jeho kontrola, recyklace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F07%2F1436" target="_blank" >GA106/07/1436: Frikční materiály na bázi polymerů s obsahem kovů a jejich vliv na životní prostředí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Slovenský časopis o chémii pre chemické vzdelávanie, výskum a priemysel
ISSN
1336-7242
e-ISSN
—
Svazek periodika
3
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
1
Strana od-do
227-227
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—