If containment of a flammable liquid is lost and the consequent vapor-air mixture is ignited, estimation of radiation from thermal radiation generated depends upon number of factors. The point source model for the prediction of thermal radiation from liquid pool fires was adopted for the evaluation of the effect distances of Pool Fire we modified the simple point source model for calculation of the effect distances directly from the mass of flammable liquid in Pool Fire. The point source model considersthe heat source (i.e. the flame) as a point that emits in all directions. The original model considers the heat received by the observer as a fraction of the heat of combustion multiplied by the burning rate. This heat decreases with the square of the distance from the source and with the transmissivity of the ambient air. In the presented model we implemented different possibilities of heat fraction calculation and we introduced the flame length in order to calculate the point source-t
Název v anglickém jazyce
Description of physical-chemical parametres of Pool-fire
Popis výsledku anglicky
If containment of a flammable liquid is lost and the consequent vapor-air mixture is ignited, estimation of radiation from thermal radiation generated depends upon number of factors. The point source model for the prediction of thermal radiation from liquid pool fires was adopted for the evaluation of the effect distances of Pool Fire we modified the simple point source model for calculation of the effect distances directly from the mass of flammable liquid in Pool Fire. The point source model considersthe heat source (i.e. the flame) as a point that emits in all directions. The original model considers the heat received by the observer as a fraction of the heat of combustion multiplied by the burning rate. This heat decreases with the square of the distance from the source and with the transmissivity of the ambient air. In the presented model we implemented different possibilities of heat fraction calculation and we introduced the flame length in order to calculate the point source-t
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AQ - Bezpečnost a ochrana zdraví, člověk – stroj
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Časopis výzkumu a aplikací v profesionální bezpečnosti
ISSN
1803-3687
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
3-4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
1-8
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—