Popis výsledku v původním jazyce
The principal application of autoignition temperature (AIT) is to define the maximum acceptable surface temperature in a particular area, usually for electrical classification purpose. AIT is an important variable used to characterize the fire and explosion hazard of liquids and must be known for safe handling, storage, and transportation. In this work, the AITs of 1-pentanol and its binary mixtures with water are measured in compliance with the EN 14522:2005 and ASTM E659 method. The measured AITs are (288+-1.5 oC, 298+-1.5 oC), and for 1-pentanol and 1-pentanol+water mixtures, respectively. It is found that the AIT reported in DIPPR 2012 and HCH is in the reproducibility, and the difference is up to 10 oC. The ISCS, SFPE, Merck reports the AIT beyond the reproducibility in with differences of 32 oC, 152 oC and 22 oC. Measured AIT of 1-pentanol conducted with 12% of water will result in a value higher than the one without water by 10 oC.
Název v anglickém jazyce
Autoignition temperature of 1-pentanol and ITs binary mixtures with water
Popis výsledku anglicky
The principal application of autoignition temperature (AIT) is to define the maximum acceptable surface temperature in a particular area, usually for electrical classification purpose. AIT is an important variable used to characterize the fire and explosion hazard of liquids and must be known for safe handling, storage, and transportation. In this work, the AITs of 1-pentanol and its binary mixtures with water are measured in compliance with the EN 14522:2005 and ASTM E659 method. The measured AITs are (288+-1.5 oC, 298+-1.5 oC), and for 1-pentanol and 1-pentanol+water mixtures, respectively. It is found that the AIT reported in DIPPR 2012 and HCH is in the reproducibility, and the difference is up to 10 oC. The ISCS, SFPE, Merck reports the AIT beyond the reproducibility in with differences of 32 oC, 152 oC and 22 oC. Measured AIT of 1-pentanol conducted with 12% of water will result in a value higher than the one without water by 10 oC.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1403" target="_blank" >LO1403: Inovace pro efektivitu a životní prostředí - growth</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Engineering Transactions, Volume 53
ISSN
2283-9216
e-ISSN
—
Svazek periodika
53
Číslo periodika v rámci svazku
neuveden
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
6
Strana od-do
43-48
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84988728233