The distinctive changes of particles' numeric concentrations, are caused by electrostatic flue gases cleaning
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27650%2F18%3A10239292" target="_blank" >RIV/61989100:27650/18:10239292 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985858:_____/18:00496261
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The distinctive changes of particles' numeric concentrations, are caused by electrostatic flue gases cleaning
Popis výsledku v původním jazyce
Using an electrostatic precipitators (further only ESP) for cleaning the flue gases from boilers, in case of brown coal burning can leads to rising of numeric particles concentrations, in front of the mass concentrations simultaneous declining. That distinctive changes have been evidenced in few concurrent measuring, were based on different principles. It was not corroborated with influence the measuring equipment by the residual electric charge of particles. This phenomenon is not a measurement error, and it is unfairly to ruling it out. Cumulative numeric particles concentration rising was identified due to rising of the concentration the 17 nm fraction. This distinctive effect finds it's explaining with sulfuric acid homogeneous nucleation and it have to be considering in new gas cleaning apparatus design and operating.
Název v anglickém jazyce
The distinctive changes of particles' numeric concentrations, are caused by electrostatic flue gases cleaning
Popis výsledku anglicky
Using an electrostatic precipitators (further only ESP) for cleaning the flue gases from boilers, in case of brown coal burning can leads to rising of numeric particles concentrations, in front of the mass concentrations simultaneous declining. That distinctive changes have been evidenced in few concurrent measuring, were based on different principles. It was not corroborated with influence the measuring equipment by the residual electric charge of particles. This phenomenon is not a measurement error, and it is unfairly to ruling it out. Cumulative numeric particles concentration rising was identified due to rising of the concentration the 17 nm fraction. This distinctive effect finds it's explaining with sulfuric acid homogeneous nucleation and it have to be considering in new gas cleaning apparatus design and operating.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník XIX. výroční konference České aerosolové společnosti: 25.-26. října 2018, Piešťany = Proceedings of 19th Annual Conference of the Czech Aerosol Society : 25th-26th October 2018, Piešťany
ISBN
978-80-270-4780-2
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
6
Strana od-do
32-37
Název nakladatele
Česká aerosolová společnost
Místo vydání
Praha
Místo konání akce
Piešťany
Datum konání akce
25. 10. 2018
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—