Explosion parameters of degas-air mixtures at elevated temperatures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27650%2F18%3A10239939" target="_blank" >RIV/61989100:27650/18:10239939 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.aidic.it/cet/18/70/000.html" target="_blank" >https://www.aidic.it/cet/18/70/000.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3303/CET1870230" target="_blank" >10.3303/CET1870230</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Explosion parameters of degas-air mixtures at elevated temperatures
Popis výsledku v původním jazyce
The maximum explosion pressure (pmax), the maximum rate of pressure rise ((dp/dt)max), the deflagration index (KG), the lower explosion limit (LEL), the upper explosion limit (UEL), have been determined in spherical explosion vessel (0.02 m3) for various degas/air mixtures ratios (0.32-2.10) at ambient initial pressure (101 kPa) and four initial temperatures (25 oC, 50 oC,100 oC, 150 oC). The outcome of this preliminary study is to quantify the dependency of explosion parameters on two variables - degas/air equivalence ratios (φ) and initial temperature (T0). These explosion characteristics are important for design of safety devices (e.g. relief systems, vents), able to ensure active protection of pressure vessels where flammable mixtures are formed. Copyright (C) 2018, AIDIC Servizi S.r.l.
Název v anglickém jazyce
Explosion parameters of degas-air mixtures at elevated temperatures
Popis výsledku anglicky
The maximum explosion pressure (pmax), the maximum rate of pressure rise ((dp/dt)max), the deflagration index (KG), the lower explosion limit (LEL), the upper explosion limit (UEL), have been determined in spherical explosion vessel (0.02 m3) for various degas/air mixtures ratios (0.32-2.10) at ambient initial pressure (101 kPa) and four initial temperatures (25 oC, 50 oC,100 oC, 150 oC). The outcome of this preliminary study is to quantify the dependency of explosion parameters on two variables - degas/air equivalence ratios (φ) and initial temperature (T0). These explosion characteristics are important for design of safety devices (e.g. relief systems, vents), able to ensure active protection of pressure vessels where flammable mixtures are formed. Copyright (C) 2018, AIDIC Servizi S.r.l.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1403" target="_blank" >LO1403: Inovace pro efektivitu a životní prostředí - growth</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Engineering Transactions. Volume 36
ISSN
2283-9216
e-ISSN
—
Svazek periodika
70
Číslo periodika v rámci svazku
srpen 2018
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
6
Strana od-do
1375-1380
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85051433034