The covered conductors faults detections
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F15%3A86096213" target="_blank" >RIV/61989100:27730/15:86096213 - isvavai.cz</a>
Výsledek na webu
<a href="http://seen.fei.tuke.sk/documents/ee2015-proceedings.pdf" target="_blank" >http://seen.fei.tuke.sk/documents/ee2015-proceedings.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The covered conductors faults detections
Popis výsledku v původním jazyce
The medium voltage covered conductors are primary specified for the forested and broken terrain by reason of theirs high reliability. The major advantages of the covered conductors include high operational reliability as there is no short-circuit at themoment of the phase-tophase contact, the individual phases may be located closer to one other and the demand on the built-up area of the supply lines is lower than that for the conductors with ACSR lines, there is no immediate phase-to-phase contact whenthe tree branch falls on the conductor, lines are not dangerous for birds sitting on the conductors. However, the main problem of theirs use is problematic fault detection for case of covered conductor downfall to the ground or for case of tree branch downfall on the covered conductor. The paper presents possibility of covered conductor faults detection with using a novel method whereas this method works on principle of partial discharges activity evaluation.
Název v anglickém jazyce
The covered conductors faults detections
Popis výsledku anglicky
The medium voltage covered conductors are primary specified for the forested and broken terrain by reason of theirs high reliability. The major advantages of the covered conductors include high operational reliability as there is no short-circuit at themoment of the phase-tophase contact, the individual phases may be located closer to one other and the demand on the built-up area of the supply lines is lower than that for the conductors with ACSR lines, there is no immediate phase-to-phase contact whenthe tree branch falls on the conductor, lines are not dangerous for birds sitting on the conductors. However, the main problem of theirs use is problematic fault detection for case of covered conductor downfall to the ground or for case of tree branch downfall on the covered conductor. The paper presents possibility of covered conductor faults detection with using a novel method whereas this method works on principle of partial discharges activity evaluation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings Of The 8th International Scientific Symposium On Electrical Power Engineering (Elektroenergetika 2015)
ISBN
978-80-553-2187-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
392-396
Název nakladatele
TECHNICAL UNIV KOSICE, FAC ELECTRICAL ENGRG & INFORMATICS
Místo vydání
Košice
Místo konání akce
Stara Lesna
Datum konání akce
16. 9. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000361561700095