Monitoring of air tunnels in a cylindrical storage device using ECT tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F19%3A10242689" target="_blank" >RIV/61989100:27730/19:10242689 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.matec-conferences.org/articles/matecconf/abs/2019/12/matecconf_vvapol2018_01008/matecconf_vvapol2018_01008.html" target="_blank" >https://www.matec-conferences.org/articles/matecconf/abs/2019/12/matecconf_vvapol2018_01008/matecconf_vvapol2018_01008.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/matecconf/201926301008" target="_blank" >10.1051/matecconf/201926301008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monitoring of air tunnels in a cylindrical storage device using ECT tomography
Popis výsledku v původním jazyce
This article focuses on the monitoring of air tunnels in sand, which in common practice are characterised as flow disturbances in the flow of bulk materials inside storage devices, hoppers, silos etc. In this case air tunnels are monitored by the ECT (Electrical Capacitance Tomography) method. The basic principle of the ECT tomographic method is the measurement of permittivity of a measured non-conducting medium. The results gained by an ECT device are then compared with the real, precisely defined measured state. The measured results show that the monitoring of flow disturbances in storage devices using ECT is a new method which does not use optical methods during measurement.
Název v anglickém jazyce
Monitoring of air tunnels in a cylindrical storage device using ECT tomography
Popis výsledku anglicky
This article focuses on the monitoring of air tunnels in sand, which in common practice are characterised as flow disturbances in the flow of bulk materials inside storage devices, hoppers, silos etc. In this case air tunnels are monitored by the ECT (Electrical Capacitance Tomography) method. The basic principle of the ECT tomographic method is the measurement of permittivity of a measured non-conducting medium. The results gained by an ECT device are then compared with the real, precisely defined measured state. The measured results show that the monitoring of flow disturbances in storage devices using ECT is a new method which does not use optical methods during measurement.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20500 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1404" target="_blank" >LO1404: Trvale udržitelný rozvoj Centra ENET</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MATEC Web of Conferences. Volume 263
ISBN
—
ISSN
2261-236X
e-ISSN
2261-236X
Počet stran výsledku
9
Strana od-do
"nestrankovano"
Název nakladatele
EDP Sciences
Místo vydání
Paříž
Místo konání akce
Podbanské
Datum konání akce
18. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—