Investigation of thermal comfort under face masks wearing conditions in the smart building
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F25%3A10260408" target="_blank" >RIV/61989100:27730/25:10260408 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.frontiersin.org/journals/built-environment/articles/10.3389/fbuil.2024.1506681/full" target="_blank" >https://www.frontiersin.org/journals/built-environment/articles/10.3389/fbuil.2024.1506681/full</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fbuil.2024.1506681" target="_blank" >10.3389/fbuil.2024.1506681</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Investigation of thermal comfort under face masks wearing conditions in the smart building
Popis výsledku v původním jazyce
The paper analyses thermal comfort of people wearing face masks. The study took place in the selected classrooms of the smart building "Energis" located in Poland. In the experiments 100 respondents participated. They filled in the questionnaire forms, in which they expressed their subjective assessment of the indoor thermal environment. Simultaneously, measurements of the physical parameters within the rooms were performed with a microclimate meter. The results clearly show that the use of face masks influenced thermal sensations of the people - they felt warmer than without the face mask on (at the same air temperature). Moreover, the respondents who wore the masks indicated that the air was more humid in relation to the case when the masks are not applied. The comparison of the obtained actual thermal sensations of the respondents with the calculation results according to the thermal comfort model proved that the model was unable to properly predict thermal sensations of people wearing face masks.
Název v anglickém jazyce
Investigation of thermal comfort under face masks wearing conditions in the smart building
Popis výsledku anglicky
The paper analyses thermal comfort of people wearing face masks. The study took place in the selected classrooms of the smart building "Energis" located in Poland. In the experiments 100 respondents participated. They filled in the questionnaire forms, in which they expressed their subjective assessment of the indoor thermal environment. Simultaneously, measurements of the physical parameters within the rooms were performed with a microclimate meter. The results clearly show that the use of face masks influenced thermal sensations of the people - they felt warmer than without the face mask on (at the same air temperature). Moreover, the respondents who wore the masks indicated that the air was more humid in relation to the case when the masks are not applied. The comparison of the obtained actual thermal sensations of the respondents with the calculation results according to the thermal comfort model proved that the model was unable to properly predict thermal sensations of people wearing face masks.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20100 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frontiers in Built Environment
ISSN
2297-3362
e-ISSN
2297-3362
Svazek periodika
10
Číslo periodika v rámci svazku
_
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
9
Strana od-do
nestránkováno
Kód UT WoS článku
001401289600001
EID výsledku v databázi Scopus
—