Treatment of dentinal tubules by Nd:YAG laser
Popis výsledku v původním jazyce
Symptom of cervical dentine hypersensitivity attacks 10 % to 15 % of population and causes an uncomfortable pain during contact with any matter. Sealing of open dentinal tubules is one of the methods to reach insensibility. Laser as a source of coherentradiation is used to melt dentine surface layers. Melted dentine turns to hard mass with a smooth, nonporous surface. Simulation of this therapy was made in vitro by means of LASAG Nd:YAG pulsed laser system KLS 246-102. Eighty human extracted teeth werecut horizontally to obtain samples from 2 mm to 3 mm thick. Fir experiments were done on cross section surfaces to find an optimal range of laser parameters. A wide range of energies from 30 mJ to 210 mJ embedded in 0,3 ms long pulse was tested. Motionin Xand Y axes was ensured by a CNC driven table and the pulse frequency 15 Hz was chosen to have a suitable overlap of laser spots. Somo color agents were examined with the aim improve surface absorption. Scanning Electron Microscopy was
Název v anglickém jazyce
Treatment of dentinal tubules by Nd:YAG laser
Popis výsledku anglicky
Symptom of cervical dentine hypersensitivity attacks 10 % to 15 % of population and causes an uncomfortable pain during contact with any matter. Sealing of open dentinal tubules is one of the methods to reach insensibility. Laser as a source of coherentradiation is used to melt dentine surface layers. Melted dentine turns to hard mass with a smooth, nonporous surface. Simulation of this therapy was made in vitro by means of LASAG Nd:YAG pulsed laser system KLS 246-102. Eighty human extracted teeth werecut horizontally to obtain samples from 2 mm to 3 mm thick. Fir experiments were done on cross section surfaces to find an optimal range of laser parameters. A wide range of energies from 30 mJ to 210 mJ embedded in 0,3 ms long pulse was tested. Motionin Xand Y axes was ensured by a CNC driven table and the pulse frequency 15 Hz was chosen to have a suitable overlap of laser spots. Somo color agents were examined with the aim improve surface absorption. Scanning Electron Microscopy was
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NK7710" target="_blank" >NK7710: Ovlivnění cervikálního dentinu lidských extrahovaných zubů Nd:YAG laserem</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
SPIE-The International Society for Optical Engineering
ISSN
0277-786X
e-ISSN
—
Svazek periodika
N
Číslo periodika v rámci svazku
5945
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
1
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—