Submukosa tenkého střeva (SIS) při léčení bulbouretrálních struktur
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F06%3A00003179" target="_blank" >RIV/61989592:15110/06:00003179 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Small intestinal submukosa (SIS) in the treatment of bulbourethral strictures
Popis výsledku v původním jazyce
Introduction & Objectives Anterior urethral strictures that are too long to be excised and re-anastomosed are best treated with substitution urethroplasty using free graft or pedicled skin flaps. Another possibility is to use xenografts. The authors evaluate their experience with small intestinal submucosa (SIS) onlay patch in the treatment of non-resectable anterior urethral strictures from the functional point of view. Material & Methods In year 2003 from January to December SIS was used as an onlay patch in bulbar and penile urethra in 50 patients (45-73, av.56,4). Four layered SIS contains no cells therefore has no risk of rejection. Matrix is commercially available - SURGISIS SLH 4S, Cook Urological Inc. SIS was measured to fit the needed caliberwithout considering shrinkage and sutured in place with running 5-zero polyglactin sutures. The wound was closed in layers and a catheter was left in place for 3 weeks and only removed after radiological evidence of satisfactory healing
Název v anglickém jazyce
Small intestinal submukosa (SIS) in the treatment of bulbourethral strictures
Popis výsledku anglicky
Introduction & Objectives Anterior urethral strictures that are too long to be excised and re-anastomosed are best treated with substitution urethroplasty using free graft or pedicled skin flaps. Another possibility is to use xenografts. The authors evaluate their experience with small intestinal submucosa (SIS) onlay patch in the treatment of non-resectable anterior urethral strictures from the functional point of view. Material & Methods In year 2003 from January to December SIS was used as an onlay patch in bulbar and penile urethra in 50 patients (45-73, av.56,4). Four layered SIS contains no cells therefore has no risk of rejection. Matrix is commercially available - SURGISIS SLH 4S, Cook Urological Inc. SIS was measured to fit the needed caliberwithout considering shrinkage and sutured in place with running 5-zero polyglactin sutures. The wound was closed in layers and a catheter was left in place for 3 weeks and only removed after radiological evidence of satisfactory healing
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FJ - Chirurgie včetně transplantologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR7764" target="_blank" >NR7764: Použití štěpu z acelulární matrix při rekonstrukci striktur mužské močové trubice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Urology
ISSN
1569-9056
e-ISSN
—
Svazek periodika
5
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
270
Strana od-do
46
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—