Korelace mezi indexem IgG a oligoklonálními pásy při CSF vyšetření u pacientů s roztroušenou sklerózou
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F07%3A00004155" target="_blank" >RIV/61989592:15110/07:00004155 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correlation of the IgG index and oligoclonal bands in the CSF of patients with multiple sclerosis
Popis výsledku v původním jazyce
Objective: The aim of this study was to assess the correlation between IgG index values and the number of the oligoclonal IgG bands (OCB) in the cerebrospinal fluid (CSF) of patients with multiple sclerosis (MS). Material and Methods: The set of 150 patients consisted of 41 males and 109 females (aged 18?68, mean 36.6 - 10.1 years). The CSF collected by a lumbar puncture was examined evaluating intrathecal synthesis using the IgG index and determining OCB. The number of alkaline OCB in the CSF was assessed using the method of isoelectric focusation. Pearson's correlation analysis, and homogeneity 2 test , Mann-Whitney test, paired-sample t-test (parametric) and Wilcoxon signed-ranks test (nonparametric) were used to evaluate the statistical significance of the results. Results: No positive correlation between the IgG index and the number of OCB was found. Mann-Whitney test also did not demonstrate any significant difference of the IgG index values in patients both with the OCB number
Název v anglickém jazyce
Correlation of the IgG index and oligoclonal bands in the CSF of patients with multiple sclerosis
Popis výsledku anglicky
Objective: The aim of this study was to assess the correlation between IgG index values and the number of the oligoclonal IgG bands (OCB) in the cerebrospinal fluid (CSF) of patients with multiple sclerosis (MS). Material and Methods: The set of 150 patients consisted of 41 males and 109 females (aged 18?68, mean 36.6 - 10.1 years). The CSF collected by a lumbar puncture was examined evaluating intrathecal synthesis using the IgG index and determining OCB. The number of alkaline OCB in the CSF was assessed using the method of isoelectric focusation. Pearson's correlation analysis, and homogeneity 2 test , Mann-Whitney test, paired-sample t-test (parametric) and Wilcoxon signed-ranks test (nonparametric) were used to evaluate the statistical significance of the results. Results: No positive correlation between the IgG index and the number of OCB was found. Mann-Whitney test also did not demonstrate any significant difference of the IgG index values in patients both with the OCB number
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Česká a slovenská neurologie a neurochirurgie
ISSN
1210-7859
e-ISSN
—
Svazek periodika
70
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
392-394
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—