The correlation of serum immunoglobulin free light chain levels and selected biological markers in multiple myeloma
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F08%3A00006173" target="_blank" >RIV/61989592:15110/08:00006173 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00098892:_____/08:#0000358
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The correlation of serum immunoglobulin free light chain levels and selected biological markers in multiple myeloma
Popis výsledku v původním jazyce
Aims: The presented study is aimed at the evaluation of correlation of free light chains serum levels - kappa, lambda and their relation (K/L ratio) and serum levels of selected biological markers in a group of patients with multiple myeloma examined atthe time of the diagnosis. Methods: 102 patients with multiple myeloma were included in this prospective study. Free light chains serum levels were determined by Freelite TM Binding Site system, for determination of serum levels of selected parameters the following methods were used: REA thymidinekinase (TK), RIA (beta2microglobulin), ICTP, PINP, enzymoimmunoassay (sIL-6R, sVCAM-1, sICAM-1, sOPG) and quantitative enzymatic immunoassay (sHGF, sVEGF, sSyndecan-1 (sSyn-1) a sFas). Results: There was founda correlation in the kappa-group of the dominant kappa chain and serum readings of beta2m (r=0,344, p=0,005), TK (r=0,263, p=0,035), ICTP (r=0,402, p=0,001), PINP (r=0,264, p=0,039), sOPG (r=0,328, p=0,028), sSyn-1 (r=0,255, p=0,046) a sF
Název v anglickém jazyce
The correlation of serum immunoglobulin free light chain levels and selected biological markers in multiple myeloma
Popis výsledku anglicky
Aims: The presented study is aimed at the evaluation of correlation of free light chains serum levels - kappa, lambda and their relation (K/L ratio) and serum levels of selected biological markers in a group of patients with multiple myeloma examined atthe time of the diagnosis. Methods: 102 patients with multiple myeloma were included in this prospective study. Free light chains serum levels were determined by Freelite TM Binding Site system, for determination of serum levels of selected parameters the following methods were used: REA thymidinekinase (TK), RIA (beta2microglobulin), ICTP, PINP, enzymoimmunoassay (sIL-6R, sVCAM-1, sICAM-1, sOPG) and quantitative enzymatic immunoassay (sHGF, sVEGF, sSyndecan-1 (sSyn-1) a sFas). Results: There was founda correlation in the kappa-group of the dominant kappa chain and serum readings of beta2m (r=0,344, p=0,005), TK (r=0,263, p=0,035), ICTP (r=0,402, p=0,001), PINP (r=0,264, p=0,039), sOPG (r=0,328, p=0,028), sSyn-1 (r=0,255, p=0,046) a sF
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR9500" target="_blank" >NR9500: Angiogeneza, kinetika plasmocytů, parametry mikroprostředí kostní dřeně a metabolismu skeletu v diagnostice monoklonální gamapatie nejistého významu a iniciálních stádií mnohočetného myelomu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers
ISSN
1213-8118
e-ISSN
—
Svazek periodika
152
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—