Improved Glycemic Control through Continuous Glucose Sensor-Augmented Insulin Pump Therapy: Prospective Results from a Community and Academic Practice Patient Registry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F09%3A00009744" target="_blank" >RIV/61989592:15110/09:00009744 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improved Glycemic Control through Continuous Glucose Sensor-Augmented Insulin Pump Therapy: Prospective Results from a Community and Academic Practice Patient Registry
Popis výsledku v původním jazyce
Background: Contucted by highly experienced investigators with abundant time and resources, phase III studies of continuous glucose sensing (CGS) may lack generalizability to everyday clinical practice. Method: Community or academic practices in six Central and Eastern European or Mediterranean contries prospectively established an anonymized registry of consecutive patients with type 1 insulin-dependent diabvetes mellitus starting CGS-augmented insulin pump therapy with the Paradigm X22 (Medtronic MiniMed, Northridge, CA) under everyday conditions, without prior CGS with another device. We compared glycosylated hemoglobin (GHb) values before and after 3 months of CGS and assessed relationships between insulin therapy variables and glycemia-related variables at weeks 1,4, and 12 of CGS.
Název v anglickém jazyce
Improved Glycemic Control through Continuous Glucose Sensor-Augmented Insulin Pump Therapy: Prospective Results from a Community and Academic Practice Patient Registry
Popis výsledku anglicky
Background: Contucted by highly experienced investigators with abundant time and resources, phase III studies of continuous glucose sensing (CGS) may lack generalizability to everyday clinical practice. Method: Community or academic practices in six Central and Eastern European or Mediterranean contries prospectively established an anonymized registry of consecutive patients with type 1 insulin-dependent diabvetes mellitus starting CGS-augmented insulin pump therapy with the Paradigm X22 (Medtronic MiniMed, Northridge, CA) under everyday conditions, without prior CGS with another device. We compared glycosylated hemoglobin (GHb) values before and after 3 months of CGS and assessed relationships between insulin therapy variables and glycemia-related variables at weeks 1,4, and 12 of CGS.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FB - Endokrinologie, diabetologie, metabolismus, výživa
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Diabetes Science and Technology (online)
ISSN
1932-2968
e-ISSN
—
Svazek periodika
3
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—