In situ measurements of thin films in bovine serum lubricated contacts using optical interferometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F14%3A33152081" target="_blank" >RIV/61989592:15110/14:33152081 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/14:PU107268 RIV/00098892:_____/14:#0000808
Výsledek na webu
<a href="http://dx.doi.org/10.1177/0954411913517498" target="_blank" >http://dx.doi.org/10.1177/0954411913517498</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/0954411913517498" target="_blank" >10.1177/0954411913517498</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In situ measurements of thin films in bovine serum lubricated contacts using optical interferometry
Popis výsledku v původním jazyce
The aim of this study is to consider the relevance of in situ measurements of bovine serum film thickness in the optical test device that could be related to the function of the artificial hip joint. It is mainly focussed on the effect of the hydrophobicity or hydrophilicity of the transparent surface and the effect of its geometry. Film thickness measurements were performed using ball-on-disc and lens-on-disc configurations of optical test device as a function of time. Chromatic interferograms were recorded with a high-speed complementary metal-oxide semiconductor digital camera and evaluated with thin film colorimetric interferometry. It was clarified that a chromium layer covering the glass disc has a hydrophobic behaviour which supports the adsorption of proteins contained in the bovine serum solution, thereby a thicker lubricating film is formed. On the contrary, the protein film formation was not observed when the disc was covered with a silica layer having a hydrophilic behaviou
Název v anglickém jazyce
In situ measurements of thin films in bovine serum lubricated contacts using optical interferometry
Popis výsledku anglicky
The aim of this study is to consider the relevance of in situ measurements of bovine serum film thickness in the optical test device that could be related to the function of the artificial hip joint. It is mainly focussed on the effect of the hydrophobicity or hydrophilicity of the transparent surface and the effect of its geometry. Film thickness measurements were performed using ball-on-disc and lens-on-disc configurations of optical test device as a function of time. Chromatic interferograms were recorded with a high-speed complementary metal-oxide semiconductor digital camera and evaluated with thin film colorimetric interferometry. It was clarified that a chromium layer covering the glass disc has a hydrophobic behaviour which supports the adsorption of proteins contained in the bovine serum solution, thereby a thicker lubricating film is formed. On the contrary, the protein film formation was not observed when the disc was covered with a silica layer having a hydrophilic behaviou
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Proceedings of the Institution of Mechanical Engineers Part H: Journal of Engineering in Medicine
ISSN
0954-4119
e-ISSN
—
Svazek periodika
228
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
149-158
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—