Comparison of brain vessel imaging from transtemporal and transcondylar approaches using contrast-enhanced transcranial color-coded duplex sonography and Virtual Navigator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F15%3A33150755" target="_blank" >RIV/61989592:15110/15:33150755 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15120/15:33150755 RIV/00843989:_____/15:E0105071
Výsledek na webu
<a href="http://dx.doi.org/10.5507/bp.2014.064" target="_blank" >http://dx.doi.org/10.5507/bp.2014.064</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2014.064" target="_blank" >10.5507/bp.2014.064</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of brain vessel imaging from transtemporal and transcondylar approaches using contrast-enhanced transcranial color-coded duplex sonography and Virtual Navigator
Popis výsledku v původním jazyce
Aims. The transcondylar approach is a new and used for detection of chronic cerebro-spinal venous insufficiency (CCSVI) and intracranial venous reflux in patients with multiple sclerosis. The aim of this study was to assess the ability of native and contrast enhanced (CE-) transcranial color-coded duplex sonography (TCCS) to detect flow and reflux in deep cerebral veins and intracranial venous sinuses from transcondylar and transtemporal approaches. Methods. Brain magnetic resonance imaging and TCCS from transtemporal and transcondylar approaches using the new technology - Fusion Imaging - in 8 volunteers and 5 patients with multiple sclerosis. Results. Using TCCS and CE-TCCS, the arteries of the circle of Willis could be detected from the transtemporal approach in 13/13 subjects in both examinations, while detection of the venous system was possible in 7/13 and 9/13 subjects, respectively. However, the arteries of the circle of Willis and venous system were detected through the transc
Název v anglickém jazyce
Comparison of brain vessel imaging from transtemporal and transcondylar approaches using contrast-enhanced transcranial color-coded duplex sonography and Virtual Navigator
Popis výsledku anglicky
Aims. The transcondylar approach is a new and used for detection of chronic cerebro-spinal venous insufficiency (CCSVI) and intracranial venous reflux in patients with multiple sclerosis. The aim of this study was to assess the ability of native and contrast enhanced (CE-) transcranial color-coded duplex sonography (TCCS) to detect flow and reflux in deep cerebral veins and intracranial venous sinuses from transcondylar and transtemporal approaches. Methods. Brain magnetic resonance imaging and TCCS from transtemporal and transcondylar approaches using the new technology - Fusion Imaging - in 8 volunteers and 5 patients with multiple sclerosis. Results. Using TCCS and CE-TCCS, the arteries of the circle of Willis could be detected from the transtemporal approach in 13/13 subjects in both examinations, while detection of the venous system was possible in 7/13 and 9/13 subjects, respectively. However, the arteries of the circle of Willis and venous system were detected through the transc
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers-Olomouc
ISSN
1213-8118
e-ISSN
—
Svazek periodika
159
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
595-600
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—