Lubrication within hip replacements - Implication for ceramic-on-hard bearing couples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F16%3A33159300" target="_blank" >RIV/61989592:15110/16:33159300 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/16:PU118616
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S1751616116300674" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1751616116300674</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmbbm.2016.04.003" target="_blank" >10.1016/j.jmbbm.2016.04.003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lubrication within hip replacements - Implication for ceramic-on-hard bearing couples
Popis výsledku v původním jazyce
The objective of the present study is to clarify the lubrication processes within artificial joints considering the ceramic femoral heads focusing on the role of particular proteins. Two optical methods were employed; colorimetric interferometry and fluorescent microscopy. The experiments were conducted in ball-on-disc configuration, where the ball is made from ceramic (Sulox(TM), BIOLOX((R))delta) and the disc from optical glass. The measurements were realized under pure rolling, partial negative and partial positive sliding, to get a complex information about the protein film behaviour under various conditions. Moreover, two different speeds were investigated; 5.7 and 22 mm/s, respectively. The contact was lubricated by saline solutions containing albumin and γ-globulin in a ratio 2:1, while the total protein concentration was 10.5 mg/ml. Under pure rolling conditions, the film thickness gradually increases with time/rolling distance independently of material and rolling speed, while the dominant fluid constituent is albumin. In the case of negative sliding, the film formation is time/distance/speed dependent. At lower speed, both proteins contribute to film thickness; at higher speed, the effect of γ-globulin is not substantial. When the disc is faster, the character of film formation is similar to the metal component in the case of Sulox ceramic. Biolox ceramic shows a different behaviour, while for both materials, the contribution of γ-globulin increases with increasing speed. As most of the results can be well explained in terms of specific proteins, it can be concluded that the experimental approach is suitable for the investigation of protein film formation considering the ceramic materials.
Název v anglickém jazyce
Lubrication within hip replacements - Implication for ceramic-on-hard bearing couples
Popis výsledku anglicky
The objective of the present study is to clarify the lubrication processes within artificial joints considering the ceramic femoral heads focusing on the role of particular proteins. Two optical methods were employed; colorimetric interferometry and fluorescent microscopy. The experiments were conducted in ball-on-disc configuration, where the ball is made from ceramic (Sulox(TM), BIOLOX((R))delta) and the disc from optical glass. The measurements were realized under pure rolling, partial negative and partial positive sliding, to get a complex information about the protein film behaviour under various conditions. Moreover, two different speeds were investigated; 5.7 and 22 mm/s, respectively. The contact was lubricated by saline solutions containing albumin and γ-globulin in a ratio 2:1, while the total protein concentration was 10.5 mg/ml. Under pure rolling conditions, the film thickness gradually increases with time/rolling distance independently of material and rolling speed, while the dominant fluid constituent is albumin. In the case of negative sliding, the film formation is time/distance/speed dependent. At lower speed, both proteins contribute to film thickness; at higher speed, the effect of γ-globulin is not substantial. When the disc is faster, the character of film formation is similar to the metal component in the case of Sulox ceramic. Biolox ceramic shows a different behaviour, while for both materials, the contribution of γ-globulin increases with increasing speed. As most of the results can be well explained in terms of specific proteins, it can be concluded that the experimental approach is suitable for the investigation of protein film formation considering the ceramic materials.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the Mechanical Behavior of Biomedical Materials
ISSN
1751-6161
e-ISSN
—
Svazek periodika
61
Číslo periodika v rámci svazku
AUG
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
13
Strana od-do
371-383
Kód UT WoS článku
000380080400035
EID výsledku v databázi Scopus
—