Effectiveness of Orthodontic Treatment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F16%3A33162730" target="_blank" >RIV/61989592:15110/16:33162730 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.iosrjournals.org/iosr-jdms/papers/Vol15-Issue%207/Version-7/A150770107.pdf" target="_blank" >http://www.iosrjournals.org/iosr-jdms/papers/Vol15-Issue%207/Version-7/A150770107.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.9790/0853-150770107" target="_blank" >10.9790/0853-150770107</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effectiveness of Orthodontic Treatment
Popis výsledku v původním jazyce
Using PAR index / Peer Assessment Rating Index / effectiveness of orthodontic treatment was assessed in the group of patients treated with fixed and removable appliances. The group consisted of 83 patients after the end of the active phase of treatment. 34 patients were treated with removable appliances and 49 patients were treated with fixed appliances. Patients came from three orthodontic workplaces in Slovakia. In individual patients, treatment was initiated between 1st January 2010 to 31 December 2012. Measurement was carried out in dental casts made before and after the active phase of treatment using PAR meter. Results of measurement were recorded in the charts. It follows from the results of measurement that effectiveness and quality of treatment with fixed appliances was higher than in patients treated with removable appliances. In some cases of treatment with removable appliances resulting in minimal improvement, it was necessary to continue intreatment with fixed appliance.
Název v anglickém jazyce
Effectiveness of Orthodontic Treatment
Popis výsledku anglicky
Using PAR index / Peer Assessment Rating Index / effectiveness of orthodontic treatment was assessed in the group of patients treated with fixed and removable appliances. The group consisted of 83 patients after the end of the active phase of treatment. 34 patients were treated with removable appliances and 49 patients were treated with fixed appliances. Patients came from three orthodontic workplaces in Slovakia. In individual patients, treatment was initiated between 1st January 2010 to 31 December 2012. Measurement was carried out in dental casts made before and after the active phase of treatment using PAR meter. Results of measurement were recorded in the charts. It follows from the results of measurement that effectiveness and quality of treatment with fixed appliances was higher than in patients treated with removable appliances. In some cases of treatment with removable appliances resulting in minimal improvement, it was necessary to continue intreatment with fixed appliance.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IOSR Journal of Dental and Medical Sciences
ISSN
2279-0861
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
IN - Indická republika
Počet stran výsledku
7
Strana od-do
1-7
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—