Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F17%3A73585384" target="_blank" >RIV/61989592:15110/17:73585384 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/17:10366639 RIV/00179906:_____/17:10366639
Výsledek na webu
<a href="http://biomed.papers.upol.cz/pdfs/bio/2017/02/12.pdf" target="_blank" >http://biomed.papers.upol.cz/pdfs/bio/2017/02/12.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2017.014" target="_blank" >10.5507/bp.2017.014</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience
Popis výsledku v původním jazyce
AIMS: To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. METHODS: Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery.
Název v anglickém jazyce
Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience
Popis výsledku anglicky
AIMS: To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. METHODS: Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30502 - Other medical science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers-Olomouc
ISSN
1213-8118
e-ISSN
—
Svazek periodika
161
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
206-209
Kód UT WoS článku
000406522700012
EID výsledku v databázi Scopus
—