A Head-to-Head Analytical Comparison of Cobas 4800 HPV, PapilloCheck HPV Screening, and LMNX Genotyping Kit HPV GP for Detection of Human Papillomavirus DNA in Cervical and Cervicovaginal Swabs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F18%3A73590726" target="_blank" >RIV/61989592:15110/18:73590726 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pubmed/?term=A+Head-to-Head+Analytical+Comparison+of+Cobas+4800+HPV%2C+PapilloCheck+HPV+Screening%2C+and+LMNX+Genotyping+Kit+HPV+GP+for+Detection+of+Human+Papillomavirus+DNA+in+Cervical+and+Cervicovaginal+Swabs" target="_blank" >https://www.ncbi.nlm.nih.gov/pubmed/?term=A+Head-to-Head+Analytical+Comparison+of+Cobas+4800+HPV%2C+PapilloCheck+HPV+Screening%2C+and+LMNX+Genotyping+Kit+HPV+GP+for+Detection+of+Human+Papillomavirus+DNA+in+Cervical+and+Cervicovaginal+Swabs</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmoldx.2018.07.004" target="_blank" >10.1016/j.jmoldx.2018.07.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Head-to-Head Analytical Comparison of Cobas 4800 HPV, PapilloCheck HPV Screening, and LMNX Genotyping Kit HPV GP for Detection of Human Papillomavirus DNA in Cervical and Cervicovaginal Swabs
Popis výsledku v původním jazyce
High-risk human papillomavirus (hrHPV) infection is a cause of cervical cancer development. The addition of hrHPV testing to cervical cancer screening and monitoring of cervical intraepithelial neoplasia treatment improves the efficacy of screening and treatment, respectively. Self-sampling for hrHPV testing seems a promising tool for increasing patient participation in cervical cancer screening. In this project, 1198 cervical swabs obtained by physicians and 176 cervicovaginal swabs obtained by self-sampling (not collected in parallel) were analyzed for the presence of 14 hrHPV genotypes using three commercially available assays in comparison. HPV DNA was detected in 21.2% of all samples (21% of cervical swabs and 22.7% of cervicovaginal swabs). The cobas 4800 HPV Test was the most sensitive (0.983) and specific (0.992) for hrHPV detection overall. The PapilloCheck HPV-Screening and LMNX Genotyping Kit HPV GP had comparable specificity with that of the cobas (0.989 and 0.955, respectively), but lesser sensitivity (0.897 and 0.909, respectively). In physician-obtained cervical swabs, the cobas showed the highest sensitivity and specificity (0.980 and 0.994, respectively) for hrHPV detection, whereas in cervicovaginal swabs, the cobas had the highest sensitivity (1.00), but the PapilloCheck had the highest specificity (0.993). In conclusion, all of the detection methods evaluated were highly sensitive and specific for hrHPV detection from both clinician-collected cervical swabs and self-sampled cervicovaginal swabs.
Název v anglickém jazyce
A Head-to-Head Analytical Comparison of Cobas 4800 HPV, PapilloCheck HPV Screening, and LMNX Genotyping Kit HPV GP for Detection of Human Papillomavirus DNA in Cervical and Cervicovaginal Swabs
Popis výsledku anglicky
High-risk human papillomavirus (hrHPV) infection is a cause of cervical cancer development. The addition of hrHPV testing to cervical cancer screening and monitoring of cervical intraepithelial neoplasia treatment improves the efficacy of screening and treatment, respectively. Self-sampling for hrHPV testing seems a promising tool for increasing patient participation in cervical cancer screening. In this project, 1198 cervical swabs obtained by physicians and 176 cervicovaginal swabs obtained by self-sampling (not collected in parallel) were analyzed for the presence of 14 hrHPV genotypes using three commercially available assays in comparison. HPV DNA was detected in 21.2% of all samples (21% of cervical swabs and 22.7% of cervicovaginal swabs). The cobas 4800 HPV Test was the most sensitive (0.983) and specific (0.992) for hrHPV detection overall. The PapilloCheck HPV-Screening and LMNX Genotyping Kit HPV GP had comparable specificity with that of the cobas (0.989 and 0.955, respectively), but lesser sensitivity (0.897 and 0.909, respectively). In physician-obtained cervical swabs, the cobas showed the highest sensitivity and specificity (0.980 and 0.994, respectively) for hrHPV detection, whereas in cervicovaginal swabs, the cobas had the highest sensitivity (1.00), but the PapilloCheck had the highest specificity (0.993). In conclusion, all of the detection methods evaluated were highly sensitive and specific for hrHPV detection from both clinician-collected cervical swabs and self-sampled cervicovaginal swabs.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30502 - Other medical science
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF MOLECULAR DIAGNOSTICS
ISSN
1525-1578
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
849-858
Kód UT WoS článku
000448637200012