ECG non-gated multi-detector computed tomography protocol prior to catheter ablation of atrial fibrillation provides sufficient data quality with lower radiation exposure compared to ecg-gated protocol. A prospective, randomized and blinded study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F18%3A73591798" target="_blank" >RIV/61989592:15110/18:73591798 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15120/18:73591798
Výsledek na webu
<a href="http://biomed.papers.upol.cz/pdfs/bio/2018/04/10.pdf" target="_blank" >http://biomed.papers.upol.cz/pdfs/bio/2018/04/10.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2018.045" target="_blank" >10.5507/bp.2018.045</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ECG non-gated multi-detector computed tomography protocol prior to catheter ablation of atrial fibrillation provides sufficient data quality with lower radiation exposure compared to ecg-gated protocol. A prospective, randomized and blinded study
Popis výsledku v původním jazyce
Background. The role of ECG-gating in left atrium (LA) computed tomography (MDCT) imaging is not precisely defined. Methods and Results. 62 patients were randomized according to ECG gating with prospective evaluation of image quality, Volume CT Dose Index, Dose Length Product, Effective Dose and registration error between anatomical map and MDCT. We found significant difference in all radiation variables, but not in visual quality, registration error, CA duration, CA fluoroscopy time and CA fluoroscopy dose. Conclusion. Helical non-gated MDCT achieved a radiation dose more than four times lower with comparable image quality and course of ablation compared to ECG-gated protocol.
Název v anglickém jazyce
ECG non-gated multi-detector computed tomography protocol prior to catheter ablation of atrial fibrillation provides sufficient data quality with lower radiation exposure compared to ecg-gated protocol. A prospective, randomized and blinded study
Popis výsledku anglicky
Background. The role of ECG-gating in left atrium (LA) computed tomography (MDCT) imaging is not precisely defined. Methods and Results. 62 patients were randomized according to ECG gating with prospective evaluation of image quality, Volume CT Dose Index, Dose Length Product, Effective Dose and registration error between anatomical map and MDCT. We found significant difference in all radiation variables, but not in visual quality, registration error, CA duration, CA fluoroscopy time and CA fluoroscopy dose. Conclusion. Helical non-gated MDCT achieved a radiation dose more than four times lower with comparable image quality and course of ablation compared to ECG-gated protocol.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BIOMEDICAL PAPERS-OLOMOUC
ISSN
1213-8118
e-ISSN
—
Svazek periodika
162
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
310-318
Kód UT WoS článku
000457488200010
EID výsledku v databázi Scopus
2-s2.0-85057296920