Epidemiologic study of orthodontic retention procedures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F18%3A73591920" target="_blank" >RIV/61989592:15110/18:73591920 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0889540617310302?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0889540617310302?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ajodo.2017.08.013" target="_blank" >10.1016/j.ajodo.2017.08.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Epidemiologic study of orthodontic retention procedures
Popis výsledku v původním jazyce
Introduction The aims of this study were to survey current retention procedures applied by Dutch orthodontists and to examine their acquaintance with “unintentionally active retainers.” Methods A questionnaire was sent to all 306 Dutch orthodontists involved in patient treatment. Questions were clustered in 4 parts: (1) general information, (2) retention procedures, (3) characteristics of wire materials for bonded retainers, and (4) acquaintance with “unintentionally active retainers.” Results The response rate was 98%. The most applied retention modality in the maxillary arch was a combination of a removable and a bonded retainer (54%); in the mandibular arch, mainly a bonded retainer without a removable retainer was used (83%). Bonded retention was aimed to be lifelong for the maxillary arch (90%) and the mandibular arch (92%). Mean removable retention duration was 2 years. Vacuum-formed retainers were used more frequently and Hawley-type retainers less frequently. The wire materials used for bonded retainers were diverse. All orthodontists were familiar with unintentionally active retainers; 44% believed this phenomenon is caused by the properties of round multistrand wires. The opinion that unwanted changes in tooth position can arise due to the properties of round multistrand wire material was associated with changing the wire material (P <0.005). Conclusions Lifelong retention with bonded retainers continues to increase. All orthodontists were acquainted with unintentionally active retainers and their impact. There is a need to identify all causative factors of inadvertent tooth movement in relation to bonded retainers and to prevent the onset of unintentionally active retainers.
Název v anglickém jazyce
Epidemiologic study of orthodontic retention procedures
Popis výsledku anglicky
Introduction The aims of this study were to survey current retention procedures applied by Dutch orthodontists and to examine their acquaintance with “unintentionally active retainers.” Methods A questionnaire was sent to all 306 Dutch orthodontists involved in patient treatment. Questions were clustered in 4 parts: (1) general information, (2) retention procedures, (3) characteristics of wire materials for bonded retainers, and (4) acquaintance with “unintentionally active retainers.” Results The response rate was 98%. The most applied retention modality in the maxillary arch was a combination of a removable and a bonded retainer (54%); in the mandibular arch, mainly a bonded retainer without a removable retainer was used (83%). Bonded retention was aimed to be lifelong for the maxillary arch (90%) and the mandibular arch (92%). Mean removable retention duration was 2 years. Vacuum-formed retainers were used more frequently and Hawley-type retainers less frequently. The wire materials used for bonded retainers were diverse. All orthodontists were familiar with unintentionally active retainers; 44% believed this phenomenon is caused by the properties of round multistrand wires. The opinion that unwanted changes in tooth position can arise due to the properties of round multistrand wire material was associated with changing the wire material (P <0.005). Conclusions Lifelong retention with bonded retainers continues to increase. All orthodontists were acquainted with unintentionally active retainers and their impact. There is a need to identify all causative factors of inadvertent tooth movement in relation to bonded retainers and to prevent the onset of unintentionally active retainers.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS
ISSN
0889-5406
e-ISSN
—
Svazek periodika
153
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
496-504
Kód UT WoS článku
000430182500006
EID výsledku v databázi Scopus
2-s2.0-85044535861