The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F18%3A73592138" target="_blank" >RIV/61989592:15110/18:73592138 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/18:73592138
Výsledek na webu
<a href="http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242018000100200&lng=en&tlng=en" target="_blank" >http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242018000100200&lng=en&tlng=en</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1590/1807-3107/2018.vol32.0001" target="_blank" >10.1590/1807-3107/2018.vol32.0001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM.
Popis výsledku v původním jazyce
This study aimed to compare the vertical marginal gap of teeth restored with lithium disilicate crowns fabricated using CAD/CAM or by pressed ceramic approach. Twenty mandibular third molar teeth were collected after surgical extractions and prepared to receive full veneer crowns. Teeth were optically scanned and lithium disilicate blocks were used to fabricate crowns using CAD/CAM technique. Polyvinyl siloxane impressions of the prepared teeth were made and monolithic pressed lithium disilicate crowns were fabricated. The marginal gap was measured using optical microscope at 200× magnification (Keyence VHX-5000, Japan). Statistical analysis was performed using Wilcoxon test. The lithium disilicate pressed crowns had significantly smaller (p = 0.006) marginal gaps (38 ± 12 μm) than the lithium disilicate CAD/CAM crowns (45 ± 12 μm). This research indicates that lithium disilicate crowns fabricated with the press technique have measurably smaller marginal gaps compared with those fabricated with CAD/CAM technique within in vitro environments. The marginal gaps achieved by the crowns across all groups were within a clinically acceptable range.
Název v anglickém jazyce
The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM.
Popis výsledku anglicky
This study aimed to compare the vertical marginal gap of teeth restored with lithium disilicate crowns fabricated using CAD/CAM or by pressed ceramic approach. Twenty mandibular third molar teeth were collected after surgical extractions and prepared to receive full veneer crowns. Teeth were optically scanned and lithium disilicate blocks were used to fabricate crowns using CAD/CAM technique. Polyvinyl siloxane impressions of the prepared teeth were made and monolithic pressed lithium disilicate crowns were fabricated. The marginal gap was measured using optical microscope at 200× magnification (Keyence VHX-5000, Japan). Statistical analysis was performed using Wilcoxon test. The lithium disilicate pressed crowns had significantly smaller (p = 0.006) marginal gaps (38 ± 12 μm) than the lithium disilicate CAD/CAM crowns (45 ± 12 μm). This research indicates that lithium disilicate crowns fabricated with the press technique have measurably smaller marginal gaps compared with those fabricated with CAD/CAM technique within in vitro environments. The marginal gaps achieved by the crowns across all groups were within a clinically acceptable range.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Brazilian Oral Research
ISSN
1807-3107
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
Jan 22, 2018
Stát vydavatele periodika
BR - Brazilská federativní republika
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
000444369600001
EID výsledku v databázi Scopus
2-s2.0-85042508327