Content of distinct metals in periprosthetic tissues and pseudosynovial joint fluid in patients with total joint arthroplasty
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F19%3A73597787" target="_blank" >RIV/61989592:15110/19:73597787 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/19:73597787
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/full/10.1002/jbm.b.34137" target="_blank" >https://onlinelibrary.wiley.com/doi/full/10.1002/jbm.b.34137</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jbm.b.34137" target="_blank" >10.1002/jbm.b.34137</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Content of distinct metals in periprosthetic tissues and pseudosynovial joint fluid in patients with total joint arthroplasty
Popis výsledku v původním jazyce
This prospective study examined the content of metals released from total joint arthroplasty into joint fluid, whole blood and periprosthetic tissues. We determined the levels of Ti, V, Nb, Co, Cr, and Mo, using inductively coupled plasma mass spectrometry, in samples from patients who underwent reoperation of total hip or knee arthroplasty. All of the patients (n = 117) included in the study had either metal on polyethylene or ceramic on polyethylene-bearing pairs. First, our results conclusively showed that the majority of released metals were deposited in periprosthetic tissues. In this context, the bloodstream turned out to be an ineffective biomarker of the effects occurring in local tissues. Second, there was a clear time-dependent nature of metallic accumulation. Based on our extensive dataset, we found significantly elevated levels of the released metals in joint fluid and periprosthetic tissues originating from loosened implants compared to stable ones, as well as recognizable differences between the groups with stable implants and aseptic loosening. Finally, it was proved that the concentrations of metals decreased dependent on the distance of the tissue from the implant.
Název v anglickém jazyce
Content of distinct metals in periprosthetic tissues and pseudosynovial joint fluid in patients with total joint arthroplasty
Popis výsledku anglicky
This prospective study examined the content of metals released from total joint arthroplasty into joint fluid, whole blood and periprosthetic tissues. We determined the levels of Ti, V, Nb, Co, Cr, and Mo, using inductively coupled plasma mass spectrometry, in samples from patients who underwent reoperation of total hip or knee arthroplasty. All of the patients (n = 117) included in the study had either metal on polyethylene or ceramic on polyethylene-bearing pairs. First, our results conclusively showed that the majority of released metals were deposited in periprosthetic tissues. In this context, the bloodstream turned out to be an ineffective biomarker of the effects occurring in local tissues. Second, there was a clear time-dependent nature of metallic accumulation. Based on our extensive dataset, we found significantly elevated levels of the released metals in joint fluid and periprosthetic tissues originating from loosened implants compared to stable ones, as well as recognizable differences between the groups with stable implants and aseptic loosening. Finally, it was proved that the concentrations of metals decreased dependent on the distance of the tissue from the implant.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
ISSN
1552-4973
e-ISSN
—
Svazek periodika
107
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
454-462
Kód UT WoS článku
000455252200025
EID výsledku v databázi Scopus
2-s2.0-85044949749