The prototype BS-II for computer measurement of biomechanical characteristics of the human cadaverous lumbar spine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F19%3A73597806" target="_blank" >RIV/61989592:15110/19:73597806 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/19:73597806
Výsledek na webu
<a href="https://josr-online.biomedcentral.com/articles/10.1186/s13018-019-1463-8" target="_blank" >https://josr-online.biomedcentral.com/articles/10.1186/s13018-019-1463-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s13018-019-1463-8" target="_blank" >10.1186/s13018-019-1463-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The prototype BS-II for computer measurement of biomechanical characteristics of the human cadaverous lumbar spine
Popis výsledku v původním jazyce
The new second-generation computer system BS-II (Bio-Spine-II) based on the National Instruments’ development environment has been designed and constructed for evaluating the stability of various surgical fixative methods of the cadaverous lumbar spine (L1–L5). BS-II holds the measured sample using aluminum fixtures and using four computer-controlled stepper motors; it performs a circular movement (warm up of the specimen), programmatically driven extension (back bend), right and left lateral flexion (lateral bend), left and right axial torsion (rotation), and axial compression (pressure). Four strain gauges are used to measure the stiffness of the sample. The movement of individual components (vertebrae) is contactlessly monitored by two CCD (charge couple device) cameras. The obtained data are in digital form continuously stored in the computer memory for further processing.
Název v anglickém jazyce
The prototype BS-II for computer measurement of biomechanical characteristics of the human cadaverous lumbar spine
Popis výsledku anglicky
The new second-generation computer system BS-II (Bio-Spine-II) based on the National Instruments’ development environment has been designed and constructed for evaluating the stability of various surgical fixative methods of the cadaverous lumbar spine (L1–L5). BS-II holds the measured sample using aluminum fixtures and using four computer-controlled stepper motors; it performs a circular movement (warm up of the specimen), programmatically driven extension (back bend), right and left lateral flexion (lateral bend), left and right axial torsion (rotation), and axial compression (pressure). Four strain gauges are used to measure the stiffness of the sample. The movement of individual components (vertebrae) is contactlessly monitored by two CCD (charge couple device) cameras. The obtained data are in digital form continuously stored in the computer memory for further processing.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
<a href="/cs/project/TG01010080" target="_blank" >TG01010080: Efektivní transfer znalostí Univerzity Palackého v Olomouci do praxe.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Orthopaedic Surgery and Research
ISSN
1749-799X
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
"454-1"-"454-12"
Kód UT WoS článku
000508134400002
EID výsledku v databázi Scopus
2-s2.0-85077022937