O-arm navigated frameless and fiducial-less deep brain stimulation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73605624" target="_blank" >RIV/61989592:15110/20:73605624 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00098892:_____/20:N0000189
Výsledek na webu
<a href="https://www.mdpi.com/2076-3425/10/10/683/htm" target="_blank" >https://www.mdpi.com/2076-3425/10/10/683/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/brainsci10100683" target="_blank" >10.3390/brainsci10100683</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
O-arm navigated frameless and fiducial-less deep brain stimulation
Popis výsledku v původním jazyce
Object: Deep brain stimulation (DBS) is a very useful procedure for the treatment of idiopathic Parkinson’s disease (PD), essential tremor, and dystonia. The authors evaluated the accuracy of the new method used in their center for the placing of DBS electrodes. Electrodes are placed using the intraoperative O-arm™ (Medtronic)-controlled frameless and fiducial-less system, Nexframe™ (Medtronic). Accuracy was evaluated prospectively in eleven consecutive PD patients (22 electrodes). Methods: Eleven adult patients with PD were implanted using the Nexframe system without fiducials and with the intraoperative O-arm (Medtronic) system and StealthStation™ S8 navigation (Medtronic). The implantation of DBS leads was performed using multiple-cell microelectrode recording, and intraoperative test stimulation to determine thresholds for stimulation-induced adverse effects. The accuracy was checked in three different steps: (1) using the intraoperative O-arm image and its fusion with preoperative planning, (2) using multiple-cell microelectrode recording and counting the number of microelectrodes with the signal of the subthalamic nucleus (STN) and finally, (3) total error was calculated according to a postoperative CT control image fused to preoperative planning. Results: The total error of the procedure was 1.79 mm; the radial error and the vector error were 171 mm and 163 mm. Conclusions: Implantation of DBS electrodes using an O-arm navigated frameless and fiducial-less system is a very useful and technically feasible procedure with excellent patient toleration with experienced Nexframe users. The accuracy of the method was confirmed at all three steps, and it is comparable to other published results. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.
Název v anglickém jazyce
O-arm navigated frameless and fiducial-less deep brain stimulation
Popis výsledku anglicky
Object: Deep brain stimulation (DBS) is a very useful procedure for the treatment of idiopathic Parkinson’s disease (PD), essential tremor, and dystonia. The authors evaluated the accuracy of the new method used in their center for the placing of DBS electrodes. Electrodes are placed using the intraoperative O-arm™ (Medtronic)-controlled frameless and fiducial-less system, Nexframe™ (Medtronic). Accuracy was evaluated prospectively in eleven consecutive PD patients (22 electrodes). Methods: Eleven adult patients with PD were implanted using the Nexframe system without fiducials and with the intraoperative O-arm (Medtronic) system and StealthStation™ S8 navigation (Medtronic). The implantation of DBS leads was performed using multiple-cell microelectrode recording, and intraoperative test stimulation to determine thresholds for stimulation-induced adverse effects. The accuracy was checked in three different steps: (1) using the intraoperative O-arm image and its fusion with preoperative planning, (2) using multiple-cell microelectrode recording and counting the number of microelectrodes with the signal of the subthalamic nucleus (STN) and finally, (3) total error was calculated according to a postoperative CT control image fused to preoperative planning. Results: The total error of the procedure was 1.79 mm; the radial error and the vector error were 171 mm and 163 mm. Conclusions: Implantation of DBS electrodes using an O-arm navigated frameless and fiducial-less system is a very useful and technically feasible procedure with excellent patient toleration with experienced Nexframe users. The accuracy of the method was confirmed at all three steps, and it is comparable to other published results. © 2020 by the authors. Licensee MDPI, Basel, Switzerland.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30210 - Clinical neurology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Brain Sciences
ISSN
2076-3425
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
7
Strana od-do
"'683(1)'"-"'683(7)'"
Kód UT WoS článku
000584180900001
EID výsledku v databázi Scopus
2-s2.0-85091574049